应用Z-DOM技术降低MSCT腹部多期检查辐射剂量 被引量:7

Preliminary Study of Radiation Reduction of Abdomen by Applying Z-axis Automatic Tube Current Modulation Technique in Multi-slice CT Scanning
下载PDF
导出
摘要 目的:通过对比分析采用不同管电流调节技术所得的图像质量和放射剂量,探讨在MSCT肝脏多期检查中以较低的放射剂量获得较高图像质量的可行性。方法:按照统一的纳入和排除标准,随机选取68例患者行MSCT肝脏多期检查。将患者分为A、B两组,每组34例。A组采用Z-轴自动毫安调节技术(Z-DOM),B组采用常规的固定mAs技术(250mAs),2组其余扫描参数相同。由两位有经验的CT诊断医师以双盲法分别对A、B组图像进行质量评分(噪声评分和诊断可接受性评分),记录并比较2组的剂量长度乘积(DLP)和有效剂量(ED)。对两组图像质量评分、DLP及ED值的差异进行统计学分析。结果:两组各解剖层面的图像质量评分差异无统计学意义(U值492.0~575.5,P>0.05);A、B组的平均DLP和ED值分别为1005.1mGy/cm和15.1mSv及1132.3mGy/cm和17.0mSv。A组的DLP、ED明显低于B组(降低约11.2%),两组差异有统计学意义(P<0.001)。结论:在MSCT肝脏多期检查中使用Z轴自动毫安调节技术可以有效地减少受检者的辐射剂量,同时可以获得高质量的诊断图像。 Objective:To evaluate the influence of different tube current modulation techniques of multi-slice CT on image quality and radiation dosage,in order to look for a feasible low radiation dosage yet high image quality technique in abdomen CT scanning. Methods: 68 patients were randomly selected to undertake multi-phase dynamic CT scanning of liver. These patients were divided into two groups with 34 patients for each. Patients in group A undertook Z-axis automatic tube current modulation (Z-DOM) technique,and routine fixed mAs protocol (250mAs) was used in group B. The other scanning parameters were similar for the two groups. Two experienced radiologists quantitatively evaluated the image quality with double-blind method. The dosage length product (DLP) and effective dosage (ED) of these 2 groups were recorded and compared. The score of image quality, DLP and ED values were analyzed to find out any statistical differences existed. Results:There were no statistical difference in image quality scores of the anatomy planes of the two groups (U value: 492.0-575. 5, P〉0. 05). The mean DLP and ED values of the two groups were 1005. lmGy/cm, 15. 1roSy and 1132.3mGy/cm, 17.0mSv respectively. DLP and ED of group A were markedly lower than that of group B (reduce for about 11.2%) and significant statistical differences were existed (P〈0. 001). Conclusion: The overall dosage taken by patients could be effectively reduced and high quality images for clinical diagnosis could be obtained by using Z-DOM technique in multi-phase dynamic MSCT scanning for liver examination.
出处 《放射学实践》 2008年第11期1269-1272,共4页 Radiologic Practice
关键词 辐射剂量 体层摄影术 X线计算机 肝疾病 Radiation dosage Tomography,X-ray computed Liver diseases
  • 相关文献

参考文献11

  • 1Rogers LF. Radiation Exposure in CT: why so high[J]. AJR, 2001,177(2) :277.
  • 2Slovis TL. CT and Computed Radiography: the Pictures are Great, but is the Radiation dose Greater than Required[J]. AJR, 2002,179(1) :39-41.
  • 3Kalra MK, Prassad S,Saini S, et al. Clinical Comparison of Stand ard-dose and 50% Reduced-close Abdominal CT, Effect on Image Quality[J]. AJR, 2002,179(5): 1101-1106.
  • 4Menzel HG,Schibilla H, Teunen D. Guidelines on Radiation dose on the Patient[M]. Luxembourg: Official Publications of the European Communities, 2006.32-33.
  • 5Nickoloff EL, Alderson PO. Radiation Exposures to Patients from CT:Reality,Public Perception,and Poliey[J]. AJR,2001,177(): 285-287.
  • 6吴爱琴,郑文龙,许崇永,程建敏,陈宇,陈廷港.低剂量CT扫描在新生儿缺氧缺血性脑病中的应用和防护价值[J].中华放射医学与防护杂志,2006,26(5):528-530. 被引量:11
  • 7Polacin A, Kalender WA, Marchal G. Evaluation of Section Sensitivity Profiles and Image Noise in Spiral CT[J]. Radiology, 1992, 185(1) :29-35.
  • 8高建华,孙宪昶,李剑颖,李娜,夏庆堂,赵雯,戴汝平.不同前置滤线器对64层螺旋CT冠状动脉成像质量及放射剂量影响的对照研究[J].中华放射学杂志,2007,41(8):858-861. 被引量:51
  • 9Naidich DP, Marshall CH, Gribbin C, et al. Low dose CT of Lungs:Preliminary Observations[J]. Radiology, 1990, 175 ( 3 ): 729 731.
  • 10Haaga JR. Radiation Dose Management: Weighing Risk Versus Benefit[J]. AJR,2001,177(2):289-291.

二级参考文献10

  • 1刘昌盛,魏文洲,郑晓华,童世平,殷响林,杨洪飙.低剂量CT扫描对婴幼儿颅脑病变检查的防护价值[J].中华放射医学与防护杂志,2004,24(3):270-271. 被引量:67
  • 2Mayo JR,Hartman TE,Leeks SH,et al.CT of the chest:minimal tube current required for good image quality with the least radiation dose.AJR,1995,164:603-607.
  • 3Haaga JR. Radiation dose management: weighing risk versus benefit. AJR,2001,177:289-291.
  • 4Slovis TL.CT and computed radiography: the pictures are great, but is the radiation dose greater than required? AJR,2002,179: 39-41.
  • 5Rogers LF. Dose reduction in CT:how low can we go? AJR,2002,179:299.
  • 6Menzel HG, Schibilla H, Teunen D. Guidelines on radiation dose on the patient. European Guidelines on Quality Criteria for Computed Tomography. Chapter 1 ( Appendix 1 ). 2006:32-33.
  • 7Polacin A, Kalender WA, Marchal G. Evaluation of section sensitivity profiles and image noise in spiral CT. Radiology, 1992, 185:29-35.
  • 8Kaczyk JE, Du Y, Walter DJ, et al. Simulation of CT dose and contrast-to-noise as function of bowtie shape. San Diego CA Proc SPIE ,2004,5368:403-410.
  • 9Toth TL, Esmeli EC, Ikhlef A, et al. Image quality and dose optimization using novel X-ray source filters tailored to patient size. San Diego Ca Proc SPIE ,2005 ,5745 :283-291.
  • 10朱晓华,李士骏,薛永明,邵江,史景云,尤正千.胸部CT低剂量扫描的图像质量与吸收剂量关系分析[J].中华放射学杂志,2003,37(10):945-950. 被引量:136

共引文献60

同被引文献34

引证文献7

二级引证文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部