摘要 It was found that a pitch-catch signal was more sensitive than normal incidence backwall echo of longitudinal wave to subtle flaw conditions in the composites (damages, fiber orientation, low level porosity, ply waviness, and cracks). Both the strength and stiffness depend on the fiber orientation and porosity volume in the composites. The porosity content of a composite structure is critical to the strength and performance of the structure in general. The depth of the sampling volume where the pitch-catch signal came from was relatively shallow with the head- to-head miniature Rayleigh probes, but the depth can be increased by increasing the separation distance of the transmitting and receiving probes. Also, a method was utilized to determine the porosity content of a composite lay-up by processing micrograph images of the laminate. A free software package was utilized to process micrograph images of the test sample. The results from the image processing method were compared with existing data. Beam profile was characterized in unidirectional CFRP(carbon fiber reinforced plastics) using pitch-catch Rayleigh probes and the one-sided pitch-catch technique was utilized to produce C-scan images with the aid of the automatic scanner. It was found that a pitch-catch signal was more sensitive than normal incidence backwall echo of longitudinal wave to subtle flaw conditions in the composites (damages, fiber orientation, low level porosity, ply waviness, and cracks). Both the strength and stiffness depend on the fiber orientation and porosity volume in the composites. The porosity content of a composite structure is critical to the strength and performance of the structure in general. The depth of the sampling volume where the pitch-catch signal came from was relatively shallow with the head- to-head miniature Rayleigh probes, but the depth can be increased by increasing the separation distance of the transmitting and receiving probes. Also, a method was utilized to determine the porosity content of a composite lay-up by processing micrograph images of the laminate. A free software package was utilized to process micrograph images of the test sample. The results from the image processing method were compared with existing data. Beam profile was characterized in unidirectional CFRP(carbon fiber reinforced plastics) using pitch-catch Rayleigh probes and the one-sided pitch-catch technique was utilized to produce C-scan images with the aid of the automatic scanner.
出处 《Acta Mechanica Solida Sinica》 SCIE EI 2008年第4期298-307,共10页 固体力学学报(英文版)
基金 supported by Chosun University,Gwangju,Korea,during the 2007 academic year.
关键词 ply-layup orientation unidirectional CFRP beam profile pitch-catch contact mode porosity level ply-layup orientation, unidirectional CFRP, beam profile, pitch-catch contact mode,porosity level
  • 相关文献

参考文献10

  • 1Im,K.H,Kim,S.K,Yang,I.Y.Impact damage and hygrothermal effects on fatigue Bending strength of orthotropy composite laminates[].KSME International Journal.1999
  • 2Hsu,D.K.Material properties characterization for composites using ultrasonic methods[].Proceeding of Noise-Con.1994
  • 3Tippler,P.A.Physics[]..
  • 4Urabe,K,Yomoda,S.Nondestructive testing method of fiber orientation in fiber reinforced composites by microwave[].Bull of Industrial Pro Re Ins.1987
  • 5Urabe,K,Yomoda,S.Non-destructive testing method of fiber orientation and fiber content in FRP using microwave[].Progress in Science and Engineering of Composites.1982
  • 6Urabe,K.Rotative polarization system of millimetric wave for detection of fiber orientation in CFRP[].Bull of Industrial Pro Re Ins.1987
  • 7Komsky,I.N,Zgonc,K,Daniel,I.M.Ultrasonic determination of layer orientation in composite lami- nates using adaptive signal classifiers[].Review of Progress in Coloration and Related Topics.1994
  • 8Hsu,D.K,Uhl,K.M.A morphological study of porosity defects in carbon-epoxy composites[].Review of Progress in Coloration and Related Topics.1987
  • 9Connolly,M.P.The measurement of porosity in composite materials using infrared thermography[].Journal of Reinforcement Plastics and Composite.1992
  • 10.Standard test method for constituent content of composite materials[].ASTM D.2006