期刊文献+

被动法γ光子针孔成像测量Pu部件对称性的数值模拟分析 被引量:1

Numerical Simulation and Analysis on Passive Gamma Ray Pinhole Imaging to Measure Symmetry Attribution of Plutonium Component
下载PDF
导出
摘要 采用Monte-Carlo数值模拟方法,理论分析Pu部件在不同针孔装置下的γ光子辐射场分布,论证了被动法γ光子针孔成像用于测量Pu部件对称性的可行性。数值模拟分析显示:采用优化的针孔装置,可提高成像质量;针孔装置特征、物距、像距属于敏感信息,对这些因素应有限制措施,以防止敏感信息泄漏。 The gamma radiation field was theoretically simulated by Monte-Carlo method for the hypothetical plutonium components in the condition of different pinhole image collimators. The passive gamma ray pinhole image method was studied in order to measure the symmetry attribute of plutonium component. Simulation results show that the quality of image can be improved by using the optimized pinhole collimator, and the sensitive information such as pinhole collimator parameters, object distance, image distance should be treated as barrier information to prevent the release of them.
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2008年第11期988-991,共4页 Atomic Energy Science and Technology
关键词 针孔 被动法 Pu部件 pinhole passive detection plutonium component
  • 相关文献

参考文献6

  • 1Technology R&D for Arms Control. Arms control and nonproliferation technologies, NNSA/ NN/ACNT-SP01[R]. USA: NNSA, 2001.
  • 2MORTENSEN F N, SCOTT J M, COLGATE S A. How archival test data contribute to certification[J]. Los Alamos Science, 2003, 28: 38-46.
  • 3YATES G J, KING N S. High-frame-rate intensified fast optical shuttered TV cameras with selected imaging applications, LAUR-94 2557 [R]. USA: LANL, 1994.
  • 4DURRANT P T, DALLIMORE M, JUPP I D, et al. The application of pinhole and coded aperture imaging in the nuclear environment [J]. Nuel Instrum Methods Phy Res, 1999, A422: 667-671.
  • 5LEE W, CHO G. Pinhole collimator design for nuclear survey system[J]. Annals of Nuclear En ergy, 2002, 29:2 029-2 042.
  • 6FETTER S, FROLOV V A, PRILUTSKY O F, et al. Detecting nuclear warhead[J]. Science & Global Security, 1990, 1:225-320.

同被引文献7

  • 1Technology R&D for Arms Control, Arms Control and Nonproliferation Technologies, 2001, NNSA/NN/ ACNT-SP01.
  • 2MU Zhiping, LIU Yihwa. IEEE Transactions on Medical Imaging, 2006, 25(6): 701-711.
  • 3Ziock K P, Collins L W, Fabris L, et al. IEEE Transactions on Nuclear Science, 2006, 53(3): 1614-1621.
  • 4Ziock K E Gamma-ray Imaging Measurements in the ORNL Radiochemical Engineering Development Center,UCRL-TR-212339, USA, 2005.
  • 5Roques J P. Applied Optics, 1987, 26(16): 3862-3865.
  • 6Gottesman S R, Fenimore E E. Applied Optics, 1989,28(20): 4344-4352.
  • 7Fetter S, Frolov V A, Prilutsky O F, et al. Science & Global Security, 1990, 1:225-320.