期刊文献+

模型3500碘-125植入治疗粒子源的剂量学特征 被引量:1

Dosimetric parameters of model 3500 iodine-125 brachytherapy sources
下载PDF
导出
摘要 本文主要是对植入科学公司生产的模型3500碘-125植入治疗粒子源的一系列剂量学特征的研究。粒子源的各个剂量学参量通过使用蒙特卡罗方法计算得到。计算模型材料采用了两种等效水:固体水和液态水。粒子源的剂量学参量如剂量率常数、径向剂量函数和各项异性函数等的确定依照美国医学物理学家协会(American Association of Physicists in Medicine AAPM)第43次工作报告。蒙特卡罗模拟得到液态水的剂量率为0.997 cGyh-1U-1,固态水的为1.027 cGyh-1U-1。与前同类研究比较,本次研究的剂量率常数与同类研究所报道的数据较为一致。 The purpose of this study was to present dosimetric quantities iodine-125 (model 3500 produced by Implant Sciences Corporation) brachytherapy sources. The Monte Carlo method has been used to calculate the dosimetric parameters in both Solid Water (WT1) and liquid water. Dosimetrie properties, including the dose rate constant, radial dose function, and anisotropy characteristics were determined according to the American Association of Physicists in Medicine (AAPM) TG-43 protocol. The dose rate constant of the source was determined to be 0. 997cGyh^-1U^-1 in liquid water and 1.027cGyh^-1U^-1 in Solid Water. Our results of dose rate constants were found to be in good agreement with previously published data for similar source configurations.
出处 《核电子学与探测技术》 CAS CSCD 北大核心 2008年第5期978-981,1004,共5页 Nuclear Electronics & Detection Technology
基金 国家自然科学基金项目(10604045)
关键词 蒙特卡罗 MCNP4C 模型3500 碘-125 剂量率 植入治疗 Monte Carlo MNP4C Model 3500 iodine-125 Dose rate constant brachytherapy
  • 相关文献

参考文献8

  • 1Rivard M. J,Coursey B. M, DeWerd L. A, et al. Update of A.APM TaskGroup No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations [J].Med. Phys. 2004,31(3).
  • 2M. J. Rivard, Comprehensive Monte Carlo calculations of AAPM Task Group Report No. 43 dosirnetry parameters for the Model 3500 I-Plant 125I brachytherapy source [J], Appl. Radiat. 2002 , Isot. 57, 381 - 389.
  • 3Reniers B, Vynckier S and ScaUiet P, Dosimetric study of the new InterSource125 iodine seed[J]. Med. Phys. 2001,28(11): 2285-2288
  • 4CCC-700 MCNP4C Monte Carlo N-Particle Transport Code System[R], Los Alamos National Laboratory Los Alamos, New Mexico, 2000.
  • 5R. E. Wallace, Model 3500 125I brachytherapy source dosirnetric characterization [J]. Appl. Radiat. 2002,Isot. 56, 581 - 587.
  • 6Dolan J, Lia Z, Williamson JF, "Monte Carlo and experimental dosimetry of an 1251 braehytherapy seed[J]. Med.Phys. 2006,33, 4675-4684.
  • 7AliS. Meigooni, Yoe-Sein MM, Al-Otoom AY, et al. Determination of the dosimetric characteristics of InterSource 125Iodine brachytherapy source[J], Appl. Radiat. 2002,Isot 56, 589-599.
  • 8R. Wang and R. S. Sloboda, "Monte Carlo dose parameters of the BrachySeed model LS-1 brachytherapy source [J]," Appl. Radiat. 2002, Isot. 56, 805 - 813

同被引文献12