摘要 目的:评价国产低密度脂蛋白胆固醇(LDL-C)直接法检测试剂盒性能。方法:利用日立7180全自动生化分析仪对国产LDL-C试剂进行一系列方法学评价比较试验。结果:批内CV<3.0%,批间CV<4.0%;线性范围可达0.02~12.00mmol/L;抗干扰能力:当样品中血红蛋白达5000mg/L,胆红素达1000umol/L,甘油三酯达5mmol/L,以及常用的正常用量的抗凝剂,均不干扰测定结果;与某进口试剂比较,回归方程为:y=1.0619x-0.0766,r=0.9967。结论:该试剂使用方便、快速、准确,适用于自动化分析。 Objective:To appraise low density lipoprotein cholesterol (LDL-C) direct test kit produced by Sichuan Maker Science and Technology CO.,LTD.Methods:LDL-C was detected with a series of tests on HITACHI 7180 Automatic Analyzer.Results:Within-day CV was less than 3.0%;between-day CV was less than 4.0%;linearity was up to 12.00mmol/L.Method Comparison:A comparison between Point LDL-C (y) and Maker LDL-C (x) gave following Results:y=1.0619x-0.0766;r=0.9967.Conclusion:Maker reagent is easy to use,fast and accurate and suitable for automation analysis.
作者 鲍杰 张宗彬
出处 《中国医药导刊》 2008年第8期1241-1242,共2页 Chinese Journal of Medicinal Guide
关键词 低密度脂蛋白胆固醇 直接法 性能评价 low density lipoprotein cholesterol direct method specification evaluation