摘要 通过间歇试验考察了水质对中空纤维膜曝气效果的影响。结果表明,随着水中有机物和其他杂质的增加,膜曝气的氧总传质系数(KLa)和饱和溶解氧(cs)的浓度不断下降,KLa由清水时的0.01853min-1降到COD含量为900mg/L时的0.0126min-1;cs值由12.54mg/L下降为10.04mg/L。对于池塘水,其KLa和cs下降幅度超过同等COD浓度的人工配水,这可能与池塘水质的复杂性有关。 Batch tests were conducted to evaluate the influence of water quality on hollow-fibre membrane aeration performance. The results show that the overall mass transfer coefficient ( KLa ) and saturated dissolved oxygen (cs) of membrane aeration system are decreased with increasing of organic and soluble substances. The KLa is decreased from 0.018 53 min^-1 in clean water to 0.012 6 min^-1 in synthetic wastewater with COD concentration of 900 mg/L. The cs is decreased from 12.54 mg/L to 10.04 mg/L. In the case of pond water, lower values of KLa and cs are obtained compared with the synthetic wastewater of similar COD concentration, and this may be related to the complexity of pond water quality.
出处 《中国给水排水》 CAS CSCD 北大核心 2008年第23期44-47,共4页 China Water & Wastewater
基金 国家"十一五"科技支撑计划项目(2006BAB17B04) 广东省水利科技项目(粤水科[2006]122号2006-21) 深圳市南山区科技计划项目
关键词 膜曝气 氧总传质系数 饱和溶解氧 污水处理 membrane aeration overall mass transfer coefficient saturated dissolved oxygen
  • 相关文献

参考文献11

二级参考文献70

  • 1虞星炬.膜生物反应器研究进展[J].化工进展,1993,12(1):11-16. 被引量:8
  • 2张六六,许春燕,牛津立,沈志松.中空纤维膜无泡供氧过程的传质性能研究[J].膜科学与技术,2004,24(5):16-21. 被引量:16
  • 3张凤君,杜祥君,赵芝清,王爽,胡思宪.中空纤维膜作生物膜载体无泡供氧处理污水研究[J].吉林大学学报(地球科学版),2005,35(2):236-238. 被引量:10
  • 4李慧,郑斐,朱文亭.利用中空纤维膜无泡供氧[J].水处理技术,2005,31(9):42-44. 被引量:7
  • 5耳环保护局.环境监测分析方法[M].北京:环境保护局出版社,1983.94-100.
  • 6AHMED T,SEMMENS M J,VOSS M A.Energy loss characteristics of parallel flow bubbleless hollow fiber membrane aerators[J].J.Membr.Sci.,2000,171:87-96.
  • 7AHMED T,SEMMENS M J.Use of sealed-end hollow fibers for bubbleless membrane aeration:experimental studies[J].J.Membr.Sci.,1992,69:1-10.
  • 8WEISS P T,OAKLEY B T,GULLIVER J S,et al.Bubbleless fiber aerator for surface waters[J].Journal of Environmental Engineering,1996,122:631-639.
  • 9ZWISCHENBERGER J B,TAO W,BIDANI A.Intravascular membrane oxygenator and carbon dioxide removal devices:a review of performance and improvements[J].ASAIO J,1999,45:41-46.
  • 10VOSS M A,AHMED T,SEMMENS M J.Long-term performance of paralled-flow bubbleless hollow fiber membrane aerators[J].Water Environ.Res.,1999,71(1):23-30.

共引文献32

同被引文献35

  • 1方茜,韦朝海,张朝升,张可方.碳氮磷比例失调城市污水的同步脱氮除磷[J].环境污染治理技术与设备,2005,6(11):46-50. 被引量:21
  • 2Tehobanogous,G. Integrated Solid Waste Management Engi- neering :Principles and Management Issues [ M]. New York: McGraw-Hill, 1993 : 381-- 390.
  • 3建设部综合计划财务司.城市建设统计年报[R].北京:建设部综合计划财务司,2004.
  • 4Hashimoto, S. , K. Furukawa, M. Shioyama. Autotrophic denitri- fication using elemental sulphur[J]. Ferment. Technol. , 1987,65 (6):683-692.
  • 5Campos, J. L. , S. Carvalho, R. Portela, et al. Kinetics of denitrifi- cation dsing sulphur compounds: Effects of S/N ratio, endoge- nous and exogenous compounds[J]. Bioresour. Technol. , 2008, 99:1 293-1 299.
  • 6Mcadam,E. J. ,S. J. Judd. A review of membrane bioreaetor po- tential for nitrate removal from drinking water[J].Desalination, 2006,196,135-148.
  • 7Haugen,K. S. ,M. J. Semmens,P. J. Novak,et al. A novel in situ technology for the treatment of nitrate contaminated groundwa- ter[J]. Water Res. ,2002,36:3 497-3 506.
  • 8Harremoes,P. , M. H. Christensen. Denitrification with methane (denitrification reed methane) [J]. Vand, 1971,1 : 7-11.
  • 9Waki, M. , H. Yokoyama. Nitrogen removal from purified swine wastewater using biogas by semi-partitioned reactor[J]. Biore- sour. Technol. ,2008,99:5 335-5 340.
  • 10Boetius, A. , K. Ravenschlag, C. J. Schubert, et al. A marine mi- crobial consortium apparently mediating anaerobic oxidation of methane[J]. Nature, 2000,407 : 623-626.

引证文献1

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部