丘陵缓坡地带下沉庭院雨水系统设计

Storm water system design of sinking courtyard in hilly gentle slope zone
下载PDF
导出
摘要 为排除下沉庭院雨水,设计充分利用丘陵缓坡地地势,将小区雨水系统分为两套系统混合排放,高处楼幢下沉庭院与小区场地、屋面雨水合用管道采用重力流排放,低处楼幢下沉庭院雨水单独汇流集中设置提升泵站加压排放。结合工程实例,介绍了雨水重力流、水泵压力流混合排放系统的关键设计参数,并与常规方式进行了综合造价及技术指标比较。 To drain the storm water from sinking courtyard, the design made use of gentle slope in the hilly area to divide the storm water system into two systems. The rainfall on the sinking courtyards of the buildings on high place, the subdistrict yards and the roof will be drained by gravity flow, while the rainfall on the sinking courtyards of the buildings on low area will be drained to the rainwater pump station and pumped to drainage. With practical projects, this paper introduced the key design parameters of combined drainage system of gravity flow and pressure flow and compared the total cost and technology index of this system with that of normal system.
出处 《给水排水》 CSCD 北大核心 2008年第11期83-85,共3页 Water & Wastewater Engineering
关键词 下沉庭院 重力流 水泵压力流 重现期 雨水系统 Sinking yard Gravity flow Pressure flow Recurrence interval Storm water system
  • 相关文献

参考文献3

  • 1建设部工程质量安全监督与行业发展司.全国民用建筑工程设计技术措施..给水排水.北京:中国计划出版社,2003..
  • 2刘培英.高层建筑下沉式庭院和大型地下停车库雨水排水问题探讨[J].给水排水,2006,32(5):186-187.
  • 3徐冬喜,霍红.某住宅小区雨水排水设计中的几个问题[J].给水排水,2005,31(4):76-78. 被引量:4