期刊文献+

一种改进的瞬时导数法计算阻抗方法

An improved instantaneous derivative method for computing impedance
下载PDF
导出
摘要 阻抗的精确测量有利于提高继电器动作速度和准确性。导数法是微机保护中最常用的一种算法之一。传统的导数法计算阻抗精度对滤波器滤高频能力和采样频率有较高的要求。无误差修正思想虽能克服该不足,然而实时性较差。为了提高导数法计算阻抗的精度和实时性,提出了一种改进的瞬时导数法计算阻抗方法。理论推理和仿真结果都证明了该方法所需的数据窗少,有利于降低运算精度对数字滤波器滤高频能力和采样频率的高度依赖,可以实时地计算阻抗。 Accurate measuring impedance can improve the rapidness and preciseness of relay. Derivative method is one of the most using of computer protection algorithms. Traditional derivative method for computing impedance is strongly depended on the sampling and the ability of high wavelet. Error amending can overcome the two shortcomings, but less in real-time performance. An improved method of instantaneous derivative method of computing impedance is put forward in this paper to improve the preciseness and real-time performance. The extent of depending on the sampling and the ability of high wavelet can be well promoted. Mathematical reasoning progress and the simulation results show that the method proposed in this paper has better real-time performance and less length of digital filter window.
出处 《电力系统保护与控制》 EI CSCD 北大核心 2008年第21期43-46,共4页 Power System Protection and Control
关键词 导数法 继电器 瞬时导数法 微机保护算法 derivative method relay instantaneous derivative method computer-based protection algorithm