期刊文献+

退火工艺对Co_(71.8)Fe_(4.9)Nb_(0.8)Si_(7.5)B_(15)非晶薄带巨磁阻抗效应的影响 被引量:1

Influences of annealing process on giant magneto-impedance effects of Co_(71.8)Fe_(4.9)Nb_(0.8)Si_(7.5)B_(15) amorphous ribbons
原文传递
导出
摘要 采用四端法研究了退火处理工艺对Co71.8Fe4.9Nb0.8Si7.5B15非晶薄带巨磁阻抗效应的影响。结果表明,Co71.8Fe4.9Nb0.8Si7.5B15非晶薄带试样经350℃保温60 min退火处理后,样品的内应力得到有效释放,大大改善了样品的软磁特性,得到了最大的巨磁阻抗效应(GMI)。在8 MHz的交变电流频率下,得到了24%的最大磁阻抗比。XRD分析表明,样品发生晶化后将降低巨磁阻抗(GMI)效应。 The influences of annealing process on giant magneto-impedance effect of amorphous Co71.8 Fe4.9Nb0.8Si7.5B15 soft magnetic ribbons were studied by four-point method. The results show that, after that the samples annealed at 350 ℃ for 60 min, its internal stress is released and the soft magnetic properties is improved, so the maximum GMI effect has been obtained. The maximum magneto-impedance ratio is 24% at a frequency of 8 MHz. XRD pattern shows that the GMI effect will decrease after the crystallization of the samples.
出处 《金属热处理》 CAS CSCD 北大核心 2008年第11期96-98,共3页 Heat Treatment of Metals
基金 国家863高技术研究发展计划项目(2002AA302601)
关键词 Co71.8Nb0.8Si7.5B15非晶薄带 退火工艺 巨磁阻抗效应 Co71.8 Fe4.9 Nb0.8 Si7.5B15 amorphous ribbons annealing process giant magneto-impedance effect (GMI)
  • 相关文献

参考文献8

  • 1Mohri K, Kohzawa T, Kawashiwa K, et al. Magneto-inductive effect ( MI effect ) in amorphous wires [ J ]. IEEE Trans. Magn. ,1992,28(5) :3150-3152.
  • 2Knobel M, Pirota K R. Giant magneto-impedance:concepts and recent progress [ J ]. J. Magn. Magn. Mater. , 2002,242- 245 : 33-40.
  • 3Panina L V, Mohri K. Magneto-impedance effect in amorphous wires [ J ]. Appl. Phys. Lett. , 1994,65 (9) : 1189 - 1191.
  • 4Panina L V, Mohri K, Uchiyama T and Noda M. Giant magneto-impedance in Co-rich amorphous wires and films [J]. IEEE Trans. Magn. , 1995,31 (2) : 1249-1260.
  • 5Beach R S, Berkowitz A E. Sensitive field-and frequency-dependent impedance spectra of amorphous FeCoSiB wire and ribbons [ J]. J. Appl. Phys. , 1994,76(10) :6209-6213.
  • 6White R M, Voltmer F W. Direct piezoelectric coupling to surface elastic waves [ J ]. Appl. Phys. Lett. , 1965,7 ( 7 ) : 314 -316.
  • 7Wano-Wari, Arao-Machi, Tokai-Shi, Aichi-Ken. Development of amorphous wire type MI sensors for automobile use [ J ]. J. Magn. Magn. Mater. ,2002,249:375-381.
  • 8Uchiyama T, Mohri K, Shinkai M, et al. Position sensing of magnetite gel using MI sensors for brain tumor detection[ J]. IEEE Trans. Magn. , 1997,33 (5) :4266-4268.