摘要
目的:研究快速青霉素过敏皮试仪在临床应用中的安全性。方法:从2004年2月至2007年12月随机选取在我院治疗的12669例患者,并随机分为皮试仪组和皮内注射组,对比结果。结果:皮试仪组6341例,阳性38例,阳性率0.6%;皮内注射组6328例,阳性262例,阳性率4.14%,两组皮试阳性率有显著差异,根据皮试结果用药,均无严重不良反应发生。结论:青霉素快速过敏皮试仪方法简便、无痛、所需时间短、安全性强,准确性高,使用效果好,可代替皮内注射法,适合推广应用。
Objective: To study the security of the fast penicillin allergic skin test instrument in clinical application. Methods: 12669 cases were randomly divided into skin test instrument group (6341 cases) and intradermal injection group (6328 cases), and the test outcome was analyzed.Results: 38 cases (0.6%) were positive in skin test instrument group, and 262 cases (4.14%) in intradermal injection group. There are significant differences. There were not any severe side effects when the penicillin was given according to the test.Conclusion: The penicillin allergic skin test instrument is simple, painless, safe and accurate, so it can replace the intradermal injection.
出处
《四川生殖卫生学院学报》
2008年第6期34-34,39,共2页
Journal of Sichuan Reproductive Health Institute