火灾非均匀温度场中正放四角锥网架结构的临界温度 被引量:4

Critical temperature of regular pyramidic space truss in non-uniform fire temperature field
下载PDF
导出
摘要 为了保障大尺度空间建筑网架屋盖结构在火灾下的结构安全性,采用非线性有限元计算方法,按设计的结构方案对不同火灾场景下的正放四角锥网架结构进行结构全过程反应分析,得到反应结构抗火性能的临界温度.对临界温度进行参数分析,结果表明,温度场非均匀系数和结构荷载比是影响结构临界温度的关键参数.用最小二乘法对临界温度随关键参数变化的曲线进行拟合,得到正放四角锥网架结构临界温度的实用计算公式.通过算例比较表明,实用计算式可简便并偏于安全地计算正放四角锥网架结构的临界温度. To ensure fire safety design for grid roof structures of large space buildings, the whole process response of regular pyramidic space truss is analyzed by nonlinear infinite element method to calculate different structural schemes. A series of critical temperatures are used to evaluate the fire performance for regular pyramidic space trusses on non-uniform fire temperature fields. The parameters for determining the critical temperatures, structure loading ratio and the coefficient for describing the non-uniform fire temperature field were considered as the key parameters. Fitting the relation of the critical temperature with key parameters by least square method, the practical equation for determining the critical temperature of regular pyramidic space trusses can be obtained. The calculated example shows that the practical equation can calculate the critical temperature for regular pyramidic space trusses.
作者 杜咏 李国强
出处 《南京工业大学学报(自然科学版)》 CAS 2008年第6期27-31,共5页 Journal of Nanjing Tech University(Natural Science Edition)
基金 国家科技部资助项目(2005BA908B12)
关键词 钢结构 抗火 临界温度 火灾非均匀温度场 steel structure fire-resistance critical temperature non-uniform fire temperature field
  • 相关文献

参考文献7

  • 1Toh W S, Fung T C, Tan K H. Fire resistance of steel frames using classical and numerical methods [ J ]. Journal of Structural Engineering, 2001, 127 (7) : 829 - 838.
  • 2Lawson R M. Behavior of steel beam-to-column connections in fire[J]. The Structural Engineer, 1990, 68(17) :263 -271.
  • 3Wang W Y, Li G Q, Dong Y L. Experimental study and spring component modeling of extended end-plate joints in fire [J]. Journal of Constructional Steel Research, 2007, 63(8):1127-1137.
  • 4Dharma R B, Tan Kanghai. Rotational capacity of steel I-beams under fire conditions : numerical simulations [ J ]. Engineering Structures, 2007,29:2403 - 2418.
  • 5李国强,杜咏.大空间建筑顶部火灾空气升温的参数分析[J].消防科学与技术,2005,24(1):19-22. 被引量:19
  • 6严慧,董石磷.板式橡胶支座节点的设计与应用研究[J].空间结构,1995,1(2):33-40. 被引量:40
  • 7中国工程建设标准化协会.CECS200:2006建筑钢结构防火技术规范[S].北京:中国计划出版社,2006.

二级参考文献4

  • 1John H Klote. Method of predicting smoke movement in atria with application to smoke management[S]. NISTIR 5516.
  • 2Nelson HE. An engineering analysis of the early stages of fire development-the fire at the Du Pont Plaza hotel and casino [S]. December 31 1986, US National Bureau of Standards,NBSIR 87-3560 Washington DC, 1987.
  • 3Andrew H Buchanan. Structural design for fire safety,2001.
  • 4GBJ16-87(修订本),建筑设计防火规范[S].北京:中国计划出版社,1995.