期刊文献+

高效液相色谱法测定人血中氢溴酸右美沙芬浓度 被引量:2

Content determination of dextromethorphan hydrobromide in human plasma by HPLC
下载PDF
导出
摘要 目的研究氢溴酸右美沙芬在健康志愿者体内的血药浓度。方法采用高效液相色谱法测定8例健康受试者口服右美沙芬糖浆和片剂后不同时间血浆中的美沙芬浓度。结果右美沙芬在5--500 ng/ml浓度范围内呈良好线性关系(r=0.9965)。结论本法精密,准确,可用于氢溴酸右美沙芬的药动学研究。 Objective To study the concentration of dextromethorphan hydrobromide in human plasma. Methods An oral does of tablets and syrup were given to eight healthy volunteers in a randomized crossover design,respectively, the drug concentrations were determined by the HPLC. Results The dextromethorphan hydrobromide was a good linear,within a concentration range of 5 -- 500 ng/ml, r = 0. 9965. Conclusion The method is accurate and precise, it is usable for the study of clinical dextromethorphan hydrobromide pharmacokinetics.
出处 《中国实用医药》 2008年第34期46-48,共3页 China Practical Medicine
关键词 氢溴酸右美沙芬 血药浓度 高效液相色谱法 Dextromethorphan Plasma concentration HPLC
  • 相关文献

参考文献1

  • 1[1]谭世杰.治疗学的药理学基础.人民卫生出版社,1987.

同被引文献19

  • 1袁成,于燕莉,张卫星,谢继青.高效液相色谱法用于褪黑素香口胶的含量测定[J].中国生化药物杂志,2005,26(4):232-234. 被引量:7
  • 2黄胜炎.咀嚼胶释药系统[J].上海医药,2006,27(2):68-72. 被引量:6
  • 3Pharmacy student studying in pharmacy colleges and pharmacy universities. Chewing gum as drug delivery system [EB/OL]. [ 2008-10-27 ]. http:/Avww.pharmainfo chewing-gum-drug-delivery-system-0.
  • 4Biradar SS, Bhagavti ST, Hukkeri I, et al. Chewing gum as a drug delivery system[J]. J Pharm, 2005, 17(2): 112-4.
  • 5Pope LE, Khalil MH, Berg JE, et al. Pharmacokinetics of dextromethorphan after single or multiple dosing in combination with quinidine in extensive and poor metabolizers [J]. J Clin Pharmacol, 2004, 44(10): 1132-42.
  • 6Suski M, Bujak-Gizycka B, Madej J. Evaluation of morphine metabolism in presence of amantadine and dextromethorphan in human serum by high performance liquid chromatography coupled with mass spectrometry (LC/MS) method [J]. Folia Med Cracov, 2008, 49(3-4): 111-21.
  • 7EichholdI TH, Mccauley-Myers DL, Khambe DA, et al. Simultaneous determination of dextromethorphan, dextrorphan,and guaifenesin in human plasma using semi-automated liquid/ liquid extraction and gradient liquid chromatography tandem mass spectrometry[J]. J Pharm Biomed Aanal, 2007, 43(2): 586-600.
  • 8Renee DB, Steven I-IH, Thomas HE, et al. Semiautomated liquid-liquid back-extraction in a 96-well format to decrease sample preparation time for the dete ruination of dextromethorphan and dextrorphan in human plasma[J]. J Chromatogr B, 2002, 772 (1): 1-10.
  • 9Hendrickson HP, Gurley B J, Wessinger WD. Determination of dextromethorphan and its metabolites in rat serum by liquid-liquid extraction and liquid chromatography with fluorescence detection [J]. J Chromatogr B Analyt Technol Biomed Life Sci, 2003, 788 (2): 261-8.
  • 10Noehr-Jensen L, Damkier P, Bidstrup TB. The relative bioavailability of loratadine administered as a chewing gum formulation in healthy volunteers [J]. Eur J Clin Pharmacol, 2006, 62(6): 437-45.