期刊文献+

Improving depth resolution of diffuse optical tomography with an exponential adjustment method based on maximum singular value of layered sensitivity

Improving depth resolution of diffuse optical tomography with an exponential adjustment method based on maximum singular value of layered sensitivity
原文传递
导出
摘要 The sensitivity of diffuse optical tomography (DOT) imaging exponentially decreases with the increase of photon penetration depth, which leads to a poor depth resolution for DOT. In this letter, an exponential adjustment method (EAM) based on maximum singular value of layered sensitivity is proposed. Optimal depth resolution can be achieved by compensating the reduced sensitivity in the deep medium. Simulations are performed using a semi-infinite model and the simulation results show that the EAM method can substantially improve the depth resolution of deeply embedded objects in the medium. Consequently, the image quality and the reconstruction accuracy for these objects have been largely improved. The sensitivity of diffuse optical tomography (DOT) imaging exponentially decreases with the increase of photon penetration depth, which leads to a poor depth resolution for DOT. In this letter, an exponential adjustment method (EAM) based on maximum singular value of layered sensitivity is proposed. Optimal depth resolution can be achieved by compensating the reduced sensitivity in the deep medium. Simulations are performed using a semi-infinite model and the simulation results show that the EAM method can substantially improve the depth resolution of deeply embedded objects in the medium. Consequently, the image quality and the reconstruction accuracy for these objects have been largely improved.
出处 《Chinese Optics Letters》 SCIE EI CAS CSCD 2008年第12期886-888,共3页 中国光学快报(英文版)
基金 supported by the National Natural Science Foundation of China(No.60675011 and 30425004) the National"973"Program of China(No.2003CB716100) the National"863"Program of China(No.2006AA01Z132)
关键词 Diagnostic radiography Electroabsorption modulators Image quality Light absorption Medical imaging Optical tomography Diagnostic radiography Electroabsorption modulators Image quality Light absorption Medical imaging Optical tomography
  • 相关文献

参考文献10

  • 1H.Niu,P.Guo,L.Ji,Q.Zhao,T.Jiang. Opt.Ex- press . 2008
  • 2F.Gao,Y.Xue,H.Zhao,T.Kusaka,M.Ueno,Y. Yamada. Chin.Opt.Lett . 2007
  • 3J.P.Culvder,A.M.Siegel,J.Siegel,J.J.Stott,D. A.Boas. Optics Letters . 2003
  • 4B.W.Pogue,T.O.McBride,J.Prewitt,U.L.(?)sterberg,K.D.Paulsen. Applied Optics . 1999
  • 5Q.Zhao,L.Ji,T.Jiang. Optics Express . 2007
  • 6K.D.Paulsen,H.Jiang. Medical Physics . 1995
  • 7H.-J.Niu,P.Guo,T.-Z.Jiang. Lecture Notes in Computer Science . 2008
  • 8Q.Zhao,L.Ji,T.Jiang. J.Biomed.Opt . 2006
  • 9X.Song,B.W.Pogue,S.Jiang,M.M.Doyley,H.De- hghani,T.D.Tosteson,K.D.Paulsen. Applied Optics . 2004
  • 10D.A.Boas,and A.M.Dale."Simulation study of magnetic resonance imaging-guided cortically constrained diffuse optical tomography of human brain function,"[].Applied Optics.2005

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部