期刊文献+

Xe-Kr laser induced collisional ionization system and experimental preparation of its initial state: Four-photon resonant excitation

Xe-Kr laser induced collisional ionization system and experimental preparation of its initial state: Four-photon resonant excitation
下载PDF
导出
摘要 This paper proposes a novel one-colour Xe-Kr laser induced collisional ionization system. Considering the level scheme of the system, it finds that the initial state of the reaction--the four 4f levels with even J of Xe-can be prepared through method of four-photon resonant excitation by dye laser with wavelength of -440 nm. Absorption of an additional photon (the transfer laser) of the same wavelength will complete the laser induced collisional ionization process. The resonance enhanced ionization spectrum of Xe by four laser photons at -440nm is measured through time-of-flight mass spectrometry, this aims at the preparation of the initial state of the system proposed. The Stark broadening of the measured spectrum is observed and consistent with the previous study. Analysis of the measured resonance ionization spectrum implies the feasibility of -440 nm four-photon resonant excitation of the initial 4f state of the Xe Kr system proposed in this paper, which prepares for a further experiment of laser induced collisional ionization. This paper proposes a novel one-colour Xe-Kr laser induced collisional ionization system. Considering the level scheme of the system, it finds that the initial state of the reaction--the four 4f levels with even J of Xe-can be prepared through method of four-photon resonant excitation by dye laser with wavelength of -440 nm. Absorption of an additional photon (the transfer laser) of the same wavelength will complete the laser induced collisional ionization process. The resonance enhanced ionization spectrum of Xe by four laser photons at -440nm is measured through time-of-flight mass spectrometry, this aims at the preparation of the initial state of the system proposed. The Stark broadening of the measured spectrum is observed and consistent with the previous study. Analysis of the measured resonance ionization spectrum implies the feasibility of -440 nm four-photon resonant excitation of the initial 4f state of the Xe Kr system proposed in this paper, which prepares for a further experiment of laser induced collisional ionization.
出处 《Chinese Physics B》 SCIE EI CAS CSCD 2008年第12期4504-4509,共6页 中国物理B(英文版)
基金 Project supported by the National Natural Science Foundation of China (Grant Nos 10674036 and 10774033) Program for New Century Excellent Talents in University Program of Excellent Team in Harbin Institute of Technology
关键词 laser induced collision IONIZATION four-photon resonant excitation time-of-flight mass spectrometry laser induced collision, ionization, four-photon resonant excitation, time-of-flight mass spectrometry
  • 相关文献

参考文献19

  • 1Harris S E and White J C 1977 IEEE J. Q. E. 13 972
  • 2Buffa R, Cavalieri S, Eramo R, Fini L and Matera M 1995 Phys. Rev. A 52 1382
  • 3Matera M, Mazzoni M, Buffa R, Cavalieri S and Arimondo E 1987 Phys. Rev. A 36 1471
  • 4Matera M, Mazzoni M, Bianconi M, Buffa R and Fini L 1990 Phys. Rev. A 41 3766
  • 5Mazzoni M and Fini L 1993 Phys. Rev. A 48 3786
  • 6Anis F, Roudnev V, Cabrera-Trujillo R and Esry B D 2006 Phys. Rev. A 73 043414
  • 7Buffa R 1995 Opt. Lett. 20 204
  • 8Berman P R, Schuller F and Nienhuis G 1990 Phys. Rev. A 42 459
  • 9Geltman S 1992 Phys. Rev. A45 4772
  • 10Zhang H Y, Xia Y Q, Chen D Y, Xiao P, Fan R W and Ma Z G 2005 Sci. Chin. Ser. G 48 78

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部