期刊文献+

Study on the dose rate upset effect of partially depleted silicon-on-insulator static random access memory

Study on the dose rate upset effect of partially depleted silicon-on-insulator static random access memory
下载PDF
导出
摘要 This paper implements the study on the Dose Rate Upset effect of PDSOI SRAM (Partially Depleted Silicon- On-Insulator Static Random Access Memory) with the Qiangguang-I accelerator in Northwest Institute of Nuclear Technology. The SRAM (Static Random Access Memory) chips are developed by the Institute of Microelectronics of Chinese Academy of Sciences. It uses the full address test mode to determine the upset mechanisms. A specified address test is taken in the same time. The test results indicate that the upset threshold of the PDSOI SRAM is about l×10s Gy(Si)/s. However, there are a few bits upset when the dose rate reaches up to 1.58 x 109 Gy(Si)/s. The SRAM circuit can still work after the high level 3~ ray pulse. Finally, the upset mechanism is determined to be the rail span collapse by comparing the critical charge with the collected charge after γ ray pulse. The physical locations of upset cells are plotted in the layout of the SRAM to investigate the layout defect. Then, some layout optimizations are made to improve the dose rate hardened performance of the PDSOI SRAM. This paper implements the study on the Dose Rate Upset effect of PDSOI SRAM (Partially Depleted Silicon- On-Insulator Static Random Access Memory) with the Qiangguang-I accelerator in Northwest Institute of Nuclear Technology. The SRAM (Static Random Access Memory) chips are developed by the Institute of Microelectronics of Chinese Academy of Sciences. It uses the full address test mode to determine the upset mechanisms. A specified address test is taken in the same time. The test results indicate that the upset threshold of the PDSOI SRAM is about l×10s Gy(Si)/s. However, there are a few bits upset when the dose rate reaches up to 1.58 x 109 Gy(Si)/s. The SRAM circuit can still work after the high level 3~ ray pulse. Finally, the upset mechanism is determined to be the rail span collapse by comparing the critical charge with the collected charge after γ ray pulse. The physical locations of upset cells are plotted in the layout of the SRAM to investigate the layout defect. Then, some layout optimizations are made to improve the dose rate hardened performance of the PDSOI SRAM.
出处 《Chinese Physics B》 SCIE EI CAS CSCD 2008年第12期4599-4605,共7页 中国物理B(英文版)
关键词 dose rate PDSOI SRAMS upset dose rate, PDSOI, SRAMs, upset
  • 相关文献

参考文献10

  • 1Musseau O and Veronique F C 2001 IEEE Nuclear and Space Radiation Effects Conference Section HI: p90-94
  • 2Hite L R, Lu H, Houston T W, Hurta D S and Bailey W E 1992 IEEE Trans. Nucl. Sci. 39 2121
  • 3Zhang Y Q, Liu C Y, Liu J L, Wang J P, Huang Z, Xu N J, He B P, Peng H L and Yao Y J 2001 Acta Phys. Sin.50 2434
  • 4He B P, Guo H X, Gong J C, Wang G Z, Luo Y H and Li Y H 2004 Acta Phys. Sin. 53 3125
  • 5He B P, Wang G Z, Zhou H, Gong J C, Luo Y H and Jiang J H 2003 Acta Phys. Sin. 52 188
  • 6Guo H X, Chen Y S, Zhang Y M, Zhou H, Gong J C, Han F B, Guan Y and Wu G Y 2001 Acta Phys. Sin. 50 2279
  • 7Nikiforov A Y and Poljakov I V 1995 IEEE Trans. Nucl. Sci 42 2138
  • 8Nikiforov A Y and Poljakov I V 1996 IEEE Trans. Nucl. Sci 43 2659
  • 9ISE TCAD Manuals Release 9.0
  • 10Ferlet-Cavrois V, Marcandella Colladant T, Musseau O and Trans. Nucl. Sci 49 1456 C, Giraud G, Gasiot G, Fenouillet C 2002 IEEE