期刊文献+

制冷机组换热器腐蚀及防治 被引量:1

Refrigeration unit heat interchanger corrosion and prevention
下载PDF
导出
摘要 腐蚀可直接影响制冷机组换热器使用寿命,甚至影响整个制冷空调系统安全运行。腐蚀防护关系到企业生产能否正常进行和企业的经济效益。本文从分析制冷机组换热器腐蚀现象及机理入手,结合实际应用重点阐述制冷机组换热器腐蚀的防治方法。 The corrosion may the immediate influence refrigeration unit heat interchanger service life, even affects the entire refrigeration air-conditioning system safe operation. Whether does the corrosion protection relate the enterprise to produce carries on normally with enterprise's economic efficiency. This article corrodes the phenomenon and the mechanism from the analysis refrigeration unit heat interchanger obtains, the union practical application key elaboration refrigeration unit heat interchanger corrodes prevention method.
作者 何源
出处 《洁净与空调技术》 2008年第4期36-39,共4页 Contamination Control & Air-Conditioning Technology
关键词 制冷机组 换热器 腐蚀 防治 Refrigeration unit Heat interchanger corrosion prevention
  • 相关文献

参考文献6

  • 1周邦宁.空调用螺杆式制冷机[M].北京:中国建筑工业出版社,2002..
  • 2中华人民共和国机械行业标准.JB/T4329-1997容积式冷水(热泵)机组[S],1998.
  • 3杨水炎编著.化工腐蚀与防护[M].中国化工防腐蚀技术协会,1989.
  • 4魂宝明主编.金属腐蚀理论及应用[M].北京:化学工业出版社,1984.
  • 5杨水炎.全面腐蚀控制,1988,(4):1-5.
  • 6陆志兴.腐蚀与防护,1984,(3):17-19.

共引文献2

同被引文献14

  • 1王育忠.铝管换热器腐蚀原因及解决方法[J].石化技术,2005,12(3):53-54. 被引量:6
  • 2Kuznicka B. Erosion-corrosion of heat exchanger tubes. Engineering Failure Analysis, 2009, 16:2382-2387.
  • 3Moffat R J. Describing the uncertainties in experimental results. Experimental Thermal and Fluid Science, 1998, 1 (1): 3- 17.
  • 4JB/T 6914-93.
  • 5Wang C C, Webb R L, Chi K Y. Data reduction for airside performance of fin-and-tube heat exchangers. Experimental Thermal and Fluid Science, 2000, 21 (4) : 218 -226.
  • 6Li Y, Braun J E, Groll E A. Impact of fouling on the performance of filter-evaporator combinations. International Journal of Refrigeration, 2007, 30 (3) : 489- 498.
  • 7Siegel J A, Nazaroff W W. Predicting particle deposition on HVAC heat exchangers. Atmospheric Environment, 2003, 37 (39): 5587-5596.
  • 8Abd -Elhady M S, Rindt C C M, van Steenhoven A A. Optimization of flow direction to minimize particulate fouling of heat exchangers. Heat Transfer Engineering, 30 (10/ 11): 895-902, 2009.
  • 9Casanueva J F, Sanchez J, Garcia-Morales J L, et al. Portable pilot plant for evaluating marine biofouling growth and control in heat exchangers condensers. Water Science and Technology, 2003, 47 (5): 99-104.
  • 10Nebot E, Casanueva J F, Casanueva T. In situ experimental study for the optimization of chlorine dosage in seawater cooling systems. Applied Thermal Engineering, 2006, 26 (16): 1893- 1900.

引证文献1

二级引证文献10