对风机管道阀门开度控制和风机转速调节的特性曲线进行了分析与比较。介绍了Φ3.0 m×11 m水泥磨机系统风机采用变频器后的节能效果。
In this paper, study and analysis of the control over the opening size of the valve gates and the characteristic curve of the fans" frequency variable speed regulation are made and the energy - saving effects of the Ф 3.0 m× 11 m cement mill system after adopting the frequency convertor are told.
出处
《建材技术与应用》
2008年第12期11-13,共3页
Research and Application of Building Materials
关键词
收尘风机
节能
特性曲线
变频调速
dust collecting fan
energy saving
characteristic curve
frequency variable speed regulation