三维超声容积自动测量技术评价胎儿小脑蚓部发育 被引量:10

Evaluation of the fetal cerebellar vermis with three-dimensional ultrasound VOCAL technique
下载PDF
导出
摘要 目的应用三维超声容积自动测量技术检测胎儿小脑蚓部的发育,为产前筛查胎儿小脑发育异常提供理论依据。方法选择20~36孕周正常胎儿387例,应用经腹三维容积自动测量技术(VOCAL)测量小脑蚓部体积,观察胎儿小脑蚓部发育规律。结果应用VOCAL软件测量胎儿小脑蚓部体积成功率为98%。胎儿小脑蚓部体积与孕周及小脑横径呈正相关,r分别为0.98、0.98(P<0.0001)。以孕周为自变量X,小脑蚓部体积测量值为因变量Y,直线回归分析认为X与Y之间有直线关系,方程为Y=-2.17+0.12X。以小脑横径为自变量,小脑蚓部体积测量值为因变量,直线回归分析认为X与Y之间有直线关系,方程为Y=-0.94+0.06X。结论三维超声容积自动测量技术测量胎儿小脑蚓部体积有助于评价胎儿小脑蚓部的发育。 Objective To evaluate the development of fetal cerebellar vermis with 3D transabdominal ultrasound virtual organ computer-aided analysis (VOCAL) technique. Methods A total of 387 normal fetuses at 20--36 gestation weeks were examined to observe the development of fetal cerebellar vermis by measuring its volume with VOCAL technique. Results The successful rate of measurement of fetal cerebellar vermis volume by VOCAL was 98.19% (380/387). Fetal cerebellar vermis volume was positively correlated with gestational age and cerebellar diameter (r= 0.98, 0.98, respectively, P〈0. 0001,). Taking gestational age as the independent variables X, cerebellar vermis volume as the dependent variable Y, linear regression analysis showed linear relationship between X and Y, Y=-2.17±0.12X. Taking cerebellar diameter as the independent variables, cerebellar vermis volume as the dependent variable, linear regression analysis showed linear relationship between X and Y equation, Y=-0.94±0.06X. Conclusion Measurement of fetal cerebellar volume by VOCAl. is able to well evaluate the development of vermis.
出处 《中国医学影像技术》 CSCD 北大核心 2008年第11期1795-1798,共4页 Chinese Journal of Medical Imaging Technology
关键词 超声检查 胎儿 小脑蚓部 体积 Ultrasonography Fetus Cerebellar vermis Volume
  • 相关文献

参考文献10

  • 1Zalel Y, Seidmen D, Brandt N, et al. The development of the fetal vermis: an in-uteroasonographie evaluation. Ultrasound Obstet Gynecol, 2002,19(2) : 136-139.
  • 2Bromley B, Nadel A, Pauker S, et al. Closure of the cerebellar vermis: evaluation with second trimester US. Radiology, 1994, 193(3) :761-763.
  • 3Vinals F, Munoz M, Naveas J, et al. The fetal cerebellar vermis: anatomy and biometric assessment using volume contrast imaging in the C-plane (VCI-C). Ultrasound Obstet Gynecol, 2005, 26 (6) :622-627.
  • 4谢红宁,蔡丹蕾,朱云晓,李丽娟.三维超声第三平面成像监测胎儿小脑蚓部发育的研究[J].中国实用妇科与产科杂志,2006,22(1):32-34. 被引量:42
  • 5徐辉雄,徐作峰,吕明德,谢晓燕,刘丽,刘广健,黄蓓.三维超声容积自动测量技术的准确性及重复性研究[J].中国超声医学杂志,2003,19(3):232-236. 被引量:50
  • 6盛林,梁萍,董宝玮.三维超声体积精测在临床中的应用[J].中华超声影像学杂志,2005,14(1):70-73. 被引量:38
  • 7Raine-Fenning NJ, Clewes JS, Kendall NR, et al. The interobserver reliabilityand validity of volume calculation from three dimensional ultrasound datasets in the invitro setting. Ultrasound Obstet Gynecol, 2003,21(3) :283-291.
  • 8黄晓微,周毓青,常才.三维超声评价胎儿小脑体积[J].中华超声影像学杂志,2007,16(3):249-252. 被引量:7
  • 9Raine-Fenning N, Campbell B, Collier J, et al. The reproducibility of endometrial volume acquisition and measurement with the VOCAL-imaging program. Ultrasound Obstet Gynecol, 2002, 19(1) : 69275.
  • 10Chang CH, Yu CH, Chang FM, et al. The assessment of normal fetal liver volume by three-dimensional ultrasound. Ultrarasound Med Biol, 2003,29(8) :1123-1129.

二级参考文献54

  • 1[1]Liang RI, Chang FM, Yao BL, et al. Predicting birth weight by fetal upper-arm volume with use of three-dimensional ultrasonography. Am J Obstet Gynecol, 1997,177:632-638
  • 2[2]Hsieh YY, Chang CC, Lee CC, et al. Fetal renal volume assessment by three-dimensional ultrasonography. Am J Obstet Gynecol, 2000, 182: 377-379
  • 3[3]Riccabona M, Nelson TR, Pretorius DH, et al.Distance and volume measurement using three-dimensional ultrasonography. J Ultrasound Med, 1995,14:881-886
  • 4[4]Xu HX, Zhang QP,Lu MD, et al. Comparison of two-dimensional and three-dimensional sonography in evaluating fetal malformations. J Clin Ultrasound, 2002, 30:515-525
  • 5[5]Xu HX, Lu MD, Zhou YQ, et al. Three-dimensional gray scale volume rendering of the liver: preliminary clinical experience. J Ultrasound Med, 2002, 21:961-970
  • 6[6]Xu HX, Yin XY, Lu MD, et al. Estimation of liver tumor volume using a three-dimensional ultrasound volumetric system. Ultrasound Med Biol, (in press)
  • 7[7]Xu HX, Yin XY, Lu MD, et al. Comparison of three- and two-dimensional sonography in diagnosis of gallbladder diseases: preliminary experience. J Ultrasound Med, (in press).2003,22:181~191
  • 8[8]Bland JM, Altman DG. Statistical methods assessing agreement between two methods of clinical measurement. Lancet 1986; 1(8476):307-310
  • 9[9]Riccabona M, Nelson TR, Pretorius DH, et al. In vivo three-dimensional sonographic measurement of organ volume: validation in the urinary bladder.J Ultrasound Med, 1996,15:627-632
  • 10[10]Hamper UM, Trapanotto V, Robert DeJong M, et al. Three-dimensional US of the prostate: early experience. Radiology, 1999, 212:719-723

共引文献123

同被引文献140

引证文献10

二级引证文献72

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部