摘要 合成了磁性Fe3O4纳米粒子,利用3-氨基丙基三乙氧基硅烷(APS)进行硅烷化,形成表面带有氨基的磁性Fe3O4纳米复合粒子,再用戊二醛将羊抗人免疫球蛋白G抗体(anti-IgG)固定在该磁性粒子表面,通过磁力将其修饰于固体石蜡碳糊电极表面制作成免疫传感器。与标记HRP的二抗体anti-IgG结合,以对苯二酚作为电子媒介体,实现对人免疫球蛋白G(IgG)的定量检测。IgG测定线性范围为2.5~400μ/L,检出限为0.75μ/L。该免疫传感器制作简单,成本低,表面更新方便,可用于临床血清检测。 Fe3O4 magnetic nanoparticles were prepared using co-precipitation technology by the reaction between FeSO4 and FeCl3 , and then the surface of the magnetic nanoparticles were functionalized with 3-aminopropyhriethoxysilane (APS). The goat anti-human immunoglobulin G antibody was covalently linked to amino-modified particles using glutaraldehyde to form magnetic bio-nanoparticles. The resulting magnetic bio-nanoparticles were attached onto the surface of solid paraffin carbon paste electrode (SPCE) with the help of a permanent magnet to construct a new amperometic immunosensor. This immunosensor was used to analyze human immunoglobulin G (IgG). The linear range was from 2.5 to 400 μg/L. The detection limit was 0.75μg/L. The simple manipulations of construction, low cost and easy regeneration of the sensing platform were main advantages of proposed immunosensor. It can be applicable to serum detection in clinical diagnosis.
出处 《分析化学》 SCIE EI CAS CSCD 北大核心 2008年第12期1614-1618,共5页 Chinese Journal of Analytical Chemistry
基金 国家自然科学基金(No.20665003) 教育部科学研究重点项目(No.207087) 广西自然科学基金(No.0728214)项目 广西研究生教育创新计划项目(No.2007105960703M11)资助
关键词 磁性纳米粒子 免疫传感器 人免疫球蛋白G Magnetic nanoparticles, immunosensor, human immunoglobulin G
  • 相关文献

参考文献13

  • 1Fernandez Sanchez C, Costa Garca A. Anal. Chim. Acta, 1999, 402:119 -127
  • 2Feng C L, Xu Y H, Song L M. Sensors and Actuators B, 2000, 66:190 -192
  • 3Zhang T, Tian B Z. , Kong J L, Yang P Y, Liu B H. Anal. Chim. Acta, 2003, 489:199 -206
  • 4Li J S, Wu Z S, Wang H, Shen G L, Yu R Q. Sensors and Actuators B, 2005, 110:327 -334
  • 5Wang S F, Tan Y M. Chem. , 2007, 387:703 -708
  • 6赵常志,焦奎,冯春良.微型IgG免疫传感器的制备及其对人免疫球蛋白G的响应[J].分析化学,2005,33(10):1476-1478. 被引量:4
  • 7Fan C H, Wang H Y, Zhu D X, Wagner G, Li G X. Anal. Sci. , 2001, 17:273-276
  • 8Liu Z M, Yang H F, Li Y F, Liu Y L, Shen G L, Yu R Q. Sensors and Actuators B, 2006, 113:956 -962
  • 9袁永海,李建平.磁性纳米粒子固定辣根过氧化物酶的生物传感器[J].分析化学,2007,35(7):1078-1082. 被引量:10
  • 10Fuentes M, Mateo C, Guisan J M, Fernandez-Lafuente R. Biosens. Bioelectron. , 2005, 20 : 1380 - 1387

二级参考文献111

共引文献39

同被引文献111

引证文献9

二级引证文献37

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部