期刊文献+

拱顶罐抽瘪原因及防范措施分析 被引量:1

CAUSE ANALYSIS ON SHRUNKEN DOME ROOF TANK AND PREVENTIVE MEASURES
下载PDF
导出
摘要 洛阳分公司储罐压油操作不当引起拱顶储罐失稳抽瘪事故时有发生,且多数管理和操作人员认识存在偏差。结合案例,进行了较为详细的分析,提出了改进措施。 Since SH 3007-1999 Code for the design of tank farms in petrochemical storage and transportation system was put into practice, shrinking accident of dome roof tank in service remarkable decreased as a result of improved installation of breather valves.However in recent years,shrinking accidents occasionally happened at SINOPEC Luoyang Branch Company or other enterprises as a result of improper operation. Besides,most of the managerial personnel and operators have cognitive deviation.Based on a case at Luoyang Branch Company,this paper analyses the causes in detail and introduces the improvement measures.
作者 孙新宇
出处 《石油化工设计》 CAS 2008年第4期18-20,共3页 Petrochemical Design
关键词 常压储罐 抽瘪原因 改进措施 Dome roof tank Cause of shnmken tank Improvement
  • 相关文献

参考文献2

  • 1黄春芳编.原油管道输送技术[M].北京:中国石化出版社,2005.
  • 2SH3007-1999.石油化工储运系统罐区设计规范[S].[S].,..

共引文献3

同被引文献3

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部