通过分析发电机内冷水运行中遇到的问题,提出了改变内冷水小混床树脂类型,提高内冷水pH值的方法,解决了发电机内冷水水质不稳定的问题,为同类型机组内冷水水质的控制提供参考。
Through analysis on problems during generator in net cooling water system operation,the methods are put forward that change type of inner cooling small mixed bed resin,heighten pH value of inner cooling water, quality seule water qualitty instability of inner cooling water. The project and control measures arc found to take reference for same type unit.