摘要 对加氢裂化空冷器换热管内流体进行了多相流数值计算。分析了衬管尾部结构对管束失效的影响,结果表明,衬管尾部直角结构在流体下游诱发涡流,产生高剪应力区,易发生冲刷腐蚀,而45°倒角结构和1:10锥角结构较为合理;同时对管内垢物的分布对流动状态的影响进行了分析,发现垢物沿轴向分布的不均匀改变了管内流体的流速,在垢物层最厚位置之后形成高剪应力区,产生冲刷腐蚀。计算结果与在役空冷器更换下来的换热管束腐蚀泄露位置吻合。 The numerical calculation of multiphase-flowing was carried out for the fluid in the air cooler bundle in hydrogenated cracking unit and the results were detailedly analyzed. The influence of the end structure of lining pipe of the bundle on the failure was analyzed. The 90-degree end would cause vortex in fluid at backward position where the high shearing force came into being and erosion-corrosion was easily to occur. But the structures of 45-degree chamfer end and 1:10 taper could largely improve this situation. The influence of distribution of corrosion products on flowing situation of fluid was also analyzed. The velocity of flow in pipes was largely changed by non-uniform distribution of corrosion products. The high shearing force zone appeared in backward position where the products was thickest and erosion-corrosion occured. Caculation results are accordant with the failure position of the air cooler bundle.
出处 《腐蚀与防护》 CAS 北大核心 2008年第12期759-761,779,共4页 Corrosion & Protection
基金 中国石化股份有限公司科技攻关项目资助(305057)
关键词 加氢裂化空冷器 衬管 冲刷腐蚀 数值分析 Hydrogenated cracking air cooler lining pipe erosion-corrosion numerical analysis
  • 相关文献

参考文献4

二级参考文献9

  • 1齐树柏.重油高效利用加工过程中异常腐蚀的调查报告[C].日本石油产业活化中心,1990.3..
  • 2Piehl R. Survey of corrosion in hydrocracker effluent air coolers[J]. Materials Performance, 1976, 15(1): 15 - 20
  • 3Harvey C, Singh A. Mitigate failures for reactor effluent air coolers[J]. Hydrocarbon Processing, October, 1999:59 - 72
  • 4Claude Scherrer, Marc Durrieu, Gaston Jarno. Distillate and hydroprocessing: coping with corrosion with high concentrations of ammonium bisulfide in the process water [J]. Materials Performanes, 1980,11:25 - 32
  • 5Damin G, McCoy J. Prevention of corrosion in hydrodesulfurizer air coolers and condensers [J]. Materials Perfrmance, 1978, 17(12):23 - 26
  • 6Bagdasarian A J, Truax D J. Chloride Stress corrosion cracking of austenitic stainless steels in hydroprocessing units [A]. Corrosion/97[C]Houston, TX:NACE International, 1997:501
  • 7Craig Harvey, Anil Singh 著,偶国富,张立群译. Mitigate failures for reaetor effluent air eoolers [M]. HYDROCARBON PROCESSING, 1999.10.
  • 8邹滢,欧阳福生,翁惠新,胡大海.石油加工过程中的阻垢剂[J].炼油设计,2000,30(12):47-50. 被引量:13
  • 9偶国富,沈春夜.加氢裂化装置加工高硫原料油的防腐蚀对策[J].石油化工腐蚀与防护,2002,19(6):9-13. 被引量:12

共引文献58

同被引文献16

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部