火灾下防火涂料破损后钢柱的极限承载力 被引量:9

ULTIMATE BEARING CAPACITY FOR STEEL COLUMNS AFTER DAMAGE TO FIRE RETARDANT COATING IN FIRE
下载PDF
导出
摘要 为了得到火灾下防火涂料局部破损后钢柱的承载力,根据平衡微分方程,对防火涂料破损后有初弯曲和荷载偏心的两端铰接钢柱的极限承载力进行了计算和分析。并用ANSYS有限元对计算结果进行了验证,二者吻合较好。对影响承载力的参数:破损长度、破损段温度、初弯曲、荷载偏心和长细比等进行了分析。结果表明:防火涂料破损后,钢柱在火灾下承载力下降;温度越高,下降越明显;柱的初始弯曲和荷载偏心对承载力影响较大,但随着温度的升高这一影响变小;随着长细比的增加,承载力降低。 In order to understand the bearing capacity of steel column in fire after partial damage of fire retardant coating (FRC), calculation and analysis using differential equation of equilibrium are carded out to predict the bearing capacity of hinged steel column with initial flexure and load eccentricity suffering partial damage of FRC. The result is verified by employing ANSYS and good agreement is achieved. The parameters affecting the ultimate bearing capacity are analyzed, including damage length of FRC, temperature of column with damage of FRC, initial flexure, load eccentricity and slenderness ratio. The results show that the bearing capacity of column is reduced significantly when the FRC is damaged in fire, especially at the high temperature. Initial flexure and load eccentricity have great impact on the bearing capacity, but the influence decreases with the elevation of temperature. The bearing capacity is also reduced with the increase of slenderness ratio.
出处 《工程力学》 EI CSCD 北大核心 2008年第12期72-78,共7页 Engineering Mechanics
基金 国家创新研究群体科学基金(50621062) 国家自然科学基金资助(50738005) 重庆大学人才引进基金(0903005104771)
关键词 防火涂料 钢柱 承载力 初弯曲 荷载偏心 fire retardant coating steel column bearing capacity initial flexure load eccentricity
  • 相关文献

参考文献9

  • 1Tomecek D V, Milke J A. A study of the effect of partial loss of protection on the fire resistance of steel columns [J]. Fire Technology, 1993, 29(1): 3--21.
  • 2Ryder N L, Wolin S D, Milke J A. An investigation of the reduction in fire resistance of steel columns caused by loss of spray-applied fire protection [J]. Journal of Fire Protection Engineering, 2002, 12(1): 31 -- 44.
  • 3Milke JA. Analyses of the impact of loss of spray-applied fire protection on the fire resistance of steel columns [C]//Davies D Evans Ed. Fire Safety Science--Proceedings of the Seventh International Symposium. Worcester, USA,2003
  • 4Fontana M, Knobloch M. Fire resistance of steel columns with partial loss of fire protection [R]. In: Proceedings of the IABSE Symposium Shanghai 2004, Metropolitan Habitats and Infrastructure, IABSE Report Vol. 88. Shanghai, China, 2004. 352f.
  • 5Knobloch M, Raveglia E, Fontana M. Partial loss of fire protection and structural collapse of high-rise buildings [C]. In: International Congress Fire safety in tall buildings, University of Cantabria. Santander, Spain. 2006.
  • 6Kang Y, Hadjisophocleous G V, Khoo H A. The effect of partial fire protection loss on the fire resistance reduction of steel beams [C]. In: Fourth International Workshop Structures in Fire. Aveiro, Portugal, 2006. 63--74.
  • 7Pessiki Stephen, Kwon Kihyon, Lee Byoung-Jun. Fire load behaviour of steel building columns with damaged spray-applied fire resistive material [C]. In: Fourth International Workshop Structures in Fire. Aveiro, Portugal, 2006. 235--245.
  • 8王卫永,李国强,王培军.火灾下防火涂料破损后约束柱的稳定承载力[J].力学季刊,2008,29(1):120-126. 被引量:12
  • 9中国工程建设标准化协会标准.建筑钢结构防火技术规范(CECS200—2006)[S].北京,2006.

二级参考文献8

  • 1Tomecek D V, Milke J A. A study of the effect of partial loss of protection on the fire resistance of steel columns [J]. Fire Technology, 1993,29(1) : 4-21.
  • 2Ryder N L, Wolin S D, Milke, J A. An investigation of the reduction in fire resistance of steel columns caused by loss of spray-applied fire protection [J]. Journal of Fire Protection Engineering. 2002,12(1) : 31 - 44.
  • 3Milke J A. Analyses of the impact of loss of spray-applied fire protection on the fire resistance of steel columns. In: Davies D. Evans (Ed.)[C]. Fire Safety Science-Proceedings of the Seventh International Symposium, Worcester, USA, 2003.
  • 4Fontana M, Knobloch M. Fire resistance of steel columns with partial loss of fire protection [C]. In: Proccedings of the IABSE Symposium Shanghai 2004, Metropolitan Habitats and Infrastructure, IABSE Report Vol. 88, Shanghai, China, ISBN 3-85748-110-2, 2004, 352.
  • 5Kang Y, Hadjisophocleous G V, Khoo H A. The effect of partial fire protection loss on the fire resistance reduction of steel beams [C]. In: Fourth international workshop Structures in fire, Aveiro. Portugal, 2006, 63 - 74.
  • 6Stephen P I, Kihyon K, Byoung-Jun LEE. Fire load behaviour of steel building columns with damaged spray-applied fire resistive material[C]. In:Fourth international workshop Structures in fire, Aveiro, Portugal. 2006, 235- 245
  • 7Knobloch M, Raveglia E, Fontana M. Partial loss of fire protection and structural collapse of high-rise buildings[C]. In: International Congress Fire safety in tall buildings, University of Cantabria, Santander, Spain. 2006
  • 8中国工程建设标准化协会标准.建筑钢结构防火技术规范(CECS200-2006)[S].北京:2006.

共引文献12

同被引文献72

引证文献9

二级引证文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部