期刊文献+

可穿戴式柔性外骨骼人机智能系统安全性设计评价 被引量:6

Research on safety evaluation of wearable exoskeleton man-machine system
下载PDF
导出
摘要 可穿戴式柔性外骨骼人机智能系统的安全性主要取决于系统的机械结构设计、驱动器的选择和布置、保护措施和安全控制策略的设计。为了提高系统的安全性及保护操作者与周围人群的安全,通过对可穿戴式柔性外骨骼人机智能系统设计、使用、维护过程中的要点进行分析,提出了系统安全性评价方法,为今后柔性外骨骼人机智能系统的发展提供了参考。 The safety and reliability of the wearable exoskeleton man-machine system mainly depended on its mechanical design, actuation, control strategy and so on. In order to improve the system safety and reliability, the system safety evaluation criteria was proposed by researching on the system design, operation and maintenance. Attention was also devoted to the system reliability, mainly related to sensors data fusion, control architecture and fault handling. Suggestion was provided to draft rules for its safety and reliability evaluation, which can make reference for developing the exoskeleton man-machine system.
出处 《机电工程》 CAS 2008年第12期85-88,共4页 Journal of Mechanical & Electrical Engineering
关键词 可穿戴式柔性外骨骼人机智能系统 人机耦合 安全性评价方案 wearable exoskeleton man-machine system human-machine doubling safety evaluation
  • 相关文献

参考文献11

  • 1ROSEN J, BRAND M, FUCHS M B, et al. A myosignalbased powered exoskeleton system[ J]. IEEE Transactions on System, Man and Cyber netics: Part A, 2001,31 (3) :210 -222.
  • 2路甬祥,陈鹰.人机一体化系统与技术立论[J].机械工程学报,1994,30(6):1-9. 被引量:59
  • 3[作者不详]. The Cognitive Robot Compunion [ EB/OL ]. [ 2008 - 04 - 29 ]. http ://www. cogniron. org.
  • 4HUETTENRAUCH H, EKLUNDH K S. Fetch-and-carry with CERO: Observations from a Long-term User Study with a Service Robot [ C ]//11^th IEEE Inter-national Workshop on Robot and Human Interactive Communication. Bertin: [ s. n.] ,2002:25 -27.
  • 5SANTIS A D, SICILIANO B, LUCA A D, et al. An atlas of physical human-robot interaction[ J ]. Mechanism and Machine Theory, 2008,4 ( 3 ) : 253 - 270.
  • 6TORTORA G J, GRABOWSKI S R. Principles of Anatomy and Physiology[ M]. 9 th ed New York: John Wiley,2000.
  • 7VENEMAN J F, EKKELENKAMP R, KRUIDHOF R, et al. A series elastic and bowden cable based actuation system for use as torque actuator in exoskeleton-type robots [J].The International Journal of Robotics Research, 2006, 25 (5),261-281.
  • 8EPHANOV A, STOIANOVICI D. Effect of a pneumatically driven haptic interface on the perceptional capabilities of human operators [ J ]. Presence, 1998,7 ( 3 ) :290 - 307.
  • 9KIM Y S. A force reflected exoskeleton-type masterarm for human-robot interaction [ J ]. IEEE Transactions on System, Man and Cybernetics : Part A ,2005,35 ( 2 ) : 198 - 212.
  • 10CHEN Y, ZHANG J F, YANG C J, et al. Design and hybrid control of the pneumatic force-feedback systems for arm-exoskeleton by using on/off valve [ J ]. Mechantronits ,2007,17 ( 7 ) :325 - 335.

二级参考文献11