摘要
电子回旋打火保护系统由打火弧光探测器、A/D转换单元和逻辑处理单元组成。弧光探测器响应时间小于2μs,A/D转换单元和逻辑处理单元响应时间小于1μs。打火保护系统输出保护信号关断各供电电源的响应时间小于20μs。
ECRH arcing protection system consists of arcing detector, A/D converter and logical processing unit. The response time of the arcing detector is less than 2μs, and the response time of the A/D converter and logical processing unit is less than 1μs. The system could switches off all related power supplies within less than 20μs from outputting the protection signals.
出处
《核聚变与等离子体物理》
CAS
CSCD
北大核心
2008年第4期342-346,共5页
Nuclear Fusion and Plasma Physics
关键词
打火
保护信号
Arcing
Protection signal