摘要
分析了新型混合型电力滤波器的补偿原理和补偿特性,给出了主电路各个组成部分的设计方法,及有源滤波器控制策略设计。利用MATLAB/Simulink构建了仿真模型,给出了仿真模型中电路的参数,得到了仿真结果。仿真结果表明,这种新型混合型电力滤波器可有效地改善无源滤波器或者单纯有源滤波器的滤波性能,这证明了设计方法的正确性。
Shunt Hybrid Active Power Filter (SHAPF) can improve the performance of passive filter and realize harmonic suppression and reactive-load compensation in large power situation. It covers the shortage of using single passive filter or single active filter harmonic suppression and reactive-toad compensation. The principle and compensation characteristic of Shunt Hybrid Active Power Filter are analyzed by establishing single-phase equivalent circuit of SHAPF in the paper. A design method of main circuit is presented by studying the scheme of main circuit. It includes design of power filter, design of coupling transformer, design of output filter and design of control strategy of active power filter. Simulation model is established based on MATLAB/Simulink, and the parameters ofsimulationmodel are presented. The simulation result indicates the novel Shunt Hybrid Active Power Filter can improve the performance of passive filter or single active filter, the validity of circuit design is proved.
出处
《电力科学与工程》
2008年第10期13-17,共5页
Electric Power Science and Engineering