期刊文献+

内充气正比计数管测量^(37)Ar活度中壁效应的理论研究 被引量:1

Wall Effect of Internal Gas Proportional Counter in ^(37)Ar Activity Measurement
下载PDF
导出
摘要 通过分析37Ar衰变产生的X射线和俄歇电子在内充气正比计数管灵敏体积中的逃逸及计数管在37Ar活度测量中的壁效应,得出X射线在正比计数管中的逃逸是产生壁效应的主要原因,提出了压力指数外推方法。使用MCNP模拟X射线和俄歇电子在内充气正比计数管中的输运,模拟结果与理论分析结论一致。比较模拟得出的壁效应值与实验测量的壁效应值可知,实验给出的壁效应值是可信的。本工作的研究结果为37Ar测量方法提供了理论支持。 By analyzing the escape of X-ray and Auger electron generated by 37Ar, wall effect of internal gas proportional counter in 37 Ar activity measurement was studied theoretically. Escape of X-ray is the main reason for wall effect of internal gas proportional counter in 37Ar activity measurement. Thus, the exponential extrapolation method of pressure was proved correctly. X-ray and electron transport in proportional counter was simulated by MCNP, and the simulation result accords with theory analytic result. The value of the wall effect was calculated by MCNP, and it is close to experimental result. This work offers theory support for 37Ar detection.
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2008年第12期1077-1081,共5页 Atomic Energy Science and Technology
关键词 37Ar 内充气正比计数管 探测效率 壁效应 MCNP程序 37Ar internal gas proportional counter detection efficiency wall effect MCNP code
  • 相关文献

参考文献9

  • 1张利兴.禁核试核查中放射性惰性气体的监测[J].核技术,2004,27(10):770-777. 被引量:24
  • 2段荣良,刘素萍,杨晓波,陈银亮,龚健,刘书行,姚琼英,熊宗华.^(37)Ar用于视察地下核试验的尝试[J].原子能科学技术,2000,34(3):270-273. 被引量:9
  • 3BIAN ZS, LIW, DUAN R L, et al. Movable 3TAr rapid detection system (MARDS) for the OSI, CTBT/OSI/WS-8/PR/10[R]. [S. l. ]: [s. n. ], 2002.
  • 4RIEDMANN R A, PURTSCHERT R, LOOSLI H H. Report on the 3TAr standards [D]. Austria: Physics Institute, University of Berne, 2006.
  • 5LOOSLI H H, OESCHGER H. ^37 Ar and ^81 Kr in the atmosphere[J]. Earth and Planetary Science Letters, 1969, 7(1): 67-71.
  • 6向永春.能谱法测量^37Ar的实验研究[R].绵阳:中国工程物理研究院,2006.
  • 7JIN C, KELLERER, ALBRECHT M. Computations to facilitate TEPC calibration with ^37Ar [J]. Nuclear Instrument and Methods in Physics Research, 1997, A386: 450-452.
  • 8STANGA D, PICOLO J L, COURSOL N, et al. Analytical calculations of counting losses in internal gas proportional counting[J]. Applied Radiation and Isotopes, 2002(56) :231-236.
  • 9谭震宇,何延才.Monte Carlo方法计算薄膜厚度测定背散射常数C(E_0)[J].山东工业大学学报,2000,30(6):528-534. 被引量:2

二级参考文献17

  • 1谭震宇,计算物理,1993年,10卷,3期,239页
  • 2Joy D C,Scanning,1989年,11卷,176页
  • 3Sheng Y Q,Phys Stat Sol.A,1985年,92卷,121页
  • 4Document A/50/1027 of the United Nations,Comprehensive Nuclear Test-Ban Treaty, 1996
  • 5CD/NTB/WP.224, International Monitoring System Expert Group Report based on Technical Discussions held from 6 February to 3 March 1995, 1995
  • 6Bian Z S, Li W, Duan R L, et al. Movable 37Ar Rapid Detection System (MARDS) for the OSI,CTBT/OSI/WS-8/PR/10, 2002
  • 7PrepCom for CTBTO, Report of Working Group B to the Second Session of the Preparatory Commission for the Comprehensive Nuclear Test-Ban Treaty Organization,CTBT/PC/Ⅱ/1/Add.2, 1997
  • 8Brookhaven National Laboratory, the Evaluated Nuclear Structure Data File [ENSDF], http://www, nndc.bnl.gov
  • 9Bowyer T W, Abel K H. J Radioanal Nucl Chem, 1998,235(1-2): 77-81
  • 10Fontaine J P, Pointurier F, Blanchard X, et al. J Environ Radioact, 2004, 72:129-135