通过对核电站电容的失效机理以及现场电容的老化分析,讨论了电容老化和失效的区别和联系:老化将导致失效,但是失效未必由老化引起。最后根据电容老化和失效的差异,给出了对应的维修策略和改进措施。
Based on the analysis of failure mechanism and the aging of the Nuclear Power Station capacitor, the difference and relationship between aging and failure was discussed. Aging will finally result in failure whereas failure does not necessarily cause aging. The capacitor' s maintain strategy and improved measure was summarized according to the difference of aging and failure.
出处
《低压电器》
北大核心
2008年第23期11-12,61,共3页
Low Voltage Apparatus
关键词
核电站
电容
老化
失效
nuclear power station
capacitor
aging
failure