摘要 CT是计算机断层摄影术的简称。据文献报道,儿童CT检查可占全部CT检查的11%。鉴于电离辐射所致儿童潜在辐射危害比成人大,儿童CT检查已日益受到公众关注。因此研究儿童CT剂量水平,针对儿童CT检查采取相应的剂量控制措施,制定儿童CT检查规范并推广,促进儿童CT检查的合理化应用,有利于降低儿童CT检查所致危害。
出处 《中华放射医学与防护杂志》 CAS CSCD 北大核心 2008年第6期668-670,共3页 Chinese Journal of Radiological Medicine and Protection
基金 山东省卫生厅青年基金资助项目(2007WQ030)
  • 相关文献

参考文献21

  • 1Mettler FA, Wiest PW, Locken JA, et al. CT scanning: patterns of use and dose. J Radiol Prot, 2000, 20(4) :353-359.
  • 2Bertell R, Ehrle LH, Schmitz-Feuerhake I. Pediatric CT research elevates public health concerns: low-dose radiation issues are highly politicized. Int J Health Serv, 2007,37(3) :419-439.
  • 3Chapple CL, Willis S, Frame J. Effective dose in paediatric computed tomography. Phys Med Biol, 2002, 47(1):107-115.
  • 4Zankl M, Panzer W, Drexler G. The calculation of dose from external photon exposures using reference human phantoms and Monte Carlo methods, Part Ⅵ : Organ doses from computed tomographic examinations. GSF-Bericht 30/91. Neuherberg: GSF,1991.
  • 5Le Heron JC. CT Dose. Christchurch, New Zealand: National Radiation Laboratory, 1993.
  • 6Kalender WA, Schmidt B, Zankl M, et al. A PC program for estimating organ dose and effective dose values in computed tomography. Eur Radiol, 1999, 9(3) :555-562.
  • 7Stamm G, Nagel HD. CT-expo-a novel program for dose evaluation in CT. Rofo, 2002,174(12) : 1570-1576.
  • 8MeCollough C, Cody D, Edyvean S, et al. The measurement, reporting, and management of radiation dose in CT, Report of AAPM Task Group 23 of the Diagnostic Imaging Council CT Committee. New York: American Association of Physicists in Medicine (AAPM), 2008 : 11-13.
  • 9杨珂,张兴太,李福生,陈英民,李连波,于夕荣,柳怡,李炜,张显鹏.儿童CT扫描体表剂量水平与分析[J].中国辐射卫生,2006,15(4):433-433. 被引量:6
  • 10崔世民 王怡 谢文石.计算机体层成像[M].北京:人民卫生出版社,2003.123-125.

二级参考文献4

  • 1Mettler.F.A.(2001)CT scanning:patterns of use and dose[J].J.Radiol.Prot.20.353-359.
  • 2ICRP Publication 60,Recommendation of the International Commission on Radiological Protection[P].1990.
  • 3ICRP Publication 87,Managing Patient Dose in Computed Tomography[P].2000.
  • 4朱建国,邓大平,侯金鹏,冯涛,杨娟娟,高梅兰.儿科放射学中儿童辐射剂量水平与评价[J].中国辐射卫生,1999,8(2):87-88. 被引量:6

共引文献7

同被引文献46

  • 1张雪哲.正确评价影像学的临床应用[J].中日友好医院学报,2005,19(3):131-132. 被引量:1
  • 2阿信.CT应用广泛,辐射危害被低估[J].中国医学论坛报,2009,35(48):A2.
  • 3Valentin J.Managing patient dose in multi-detector computed tomography(MDCT)[J].Ann ICRP,2007,37:1-79.
  • 4Golding ST,Shrimton PC.Radiation does in CT:are we meeting the challenge?[J].Brit J Radiol,2002,75:1-4.
  • 5Colang JE,Killion JB,Vano E.Patient dose from CT:a literature review[J].Radiol Technol,2007,79:17-26.
  • 6Herzog C, Mulvihill DM, Nguyen SA, et al. Pediatric cardiovas- cular CT angiography: Radiation dose reduction using automatic anatomic tube current modulation. AJR Am J Roentgenol, 2008, 190(5) : 1232-1240.
  • 7Lee T, Tsai IC, Fu YC, et al. Using multidetector-row CT in ne- onates with complex congenital heart disease to replace diagnostic cardiac catheterization for anatomical investigation: Initial, experi- ences in technical and clinical feasibility. Pediatr Radiol, 2006,36 (12) :1273-1282.
  • 8Mayo JR, Aldrich J, Muller NL, et al. Radiation exposure at chest CT: A statement of the Fleisehner Society. Radiology, 2003,228(1) : 15-21.
  • 9Heyer CM, Mohr PS, Lemburg SP, et al. Image quality and ra- diation exposure at pulmonary CT angiography with 100- or 120- kVp protocol: prospective randomized study. Radiology, 2007, 245(2) : 577-583.
  • 10Thomas KE, Wang B. Age-specific effective doses for pediatric MSCT examinations at a large children's hospital using DLP con- version coefficients: A simple estimation method. Pediatr Radiol, 2008,38(6) : 645-656.