摘要 电站锅炉的换热器管经常发生爆破和泄漏事故,严重影响锅炉运行安全。按照换热器管的设计、制造、安装、运行和维修等先后顺序以及所处位置和运行环境的不同,论述了电站锅炉换热器管产生爆漏的原因及应采取的对策。 The burst -leakage failures occurred frequently on heat -exchanging tubes of utility boilers, seriously affect safe operation of the boilers. According to the sequence in succesion of design, manufacture,installation,and operation of the heat -exchanging tubes,as well as different positions and environments of operation, the causes leading to burst - leakage on heat - exchanging tubes of utility boilers,and countermeasures must be adopted, have been expounded, providing reference for boiler manufacture, power plant design and construction, as well as for operation and maintenance.
出处 《热力发电》 CAS 北大核心 2008年第12期35-37,53,共4页 Thermal Power Generation
关键词 电站锅炉 换热器管 水冷壁 过热器 再热器 省煤器 爆漏 utility boiler heat - exchanging tube water - wall superheater reheater economiser burst - leakage