期刊文献+

邯郸热电厂气力除灰系统存在的问题及改造 被引量:6

PROBLEMS EXISTING IN PNEUMATIC ASH HANDLING SYSTEM OF HANDAN THERMAL POWER PLANT AND RETROFIT THEREOF
下载PDF
导出
摘要 邯郸热电厂气力除灰系统在运行中存在出力不足、堵管、管道磨损、用气量大、落灰不畅等问题,对此,提出了增加仓泵容积、改进气灰混合方式、更换磨损弯头、降低输灰速度及空气系统增容改造等措施,实施后基本解决了上述问题,保证了系统运行的稳定性。 The problems existing in operation of pneumatic ash handling system in Handan Thermal Power Plant are as follows:insufficient output capacity, clogging in pipe, worn-out of pipelines, large amout of used air,and inadequate ash -dropping etc.. For these, some measures,such as increasing the capacity of depository pump,improving mixing mode of air and ash,replacing the worn-out elbows,decreasing the speed of ash handling,and retrofitting the air system to increase the capacity etc. ,have been put forward. After implementation, the ahove- mentined problems have basically been solved.ensuring the stability in operation of said system.
出处 《热力发电》 CAS 北大核心 2008年第12期45-47,共3页 Thermal Power Generation
关键词 热电厂 气力除灰 堵管 磨损 thermal power plant pneumatic ash handling clogging in pipe worn- out