期刊文献+

直接空冷机组的热态冲洗 被引量:2

HOT-STATE FLUSHING OF DIRECT AIR-COOLED UNIT
下载PDF
导出
摘要 针对覆盖过滤器投运过程中存在的问题,对直接空冷机组的热态冲洗提出了具体的冲洗方案:(1)不仅对空冷凝汽器及相应管道冲洗,还包括汽轮机侧各疏水管道和排汽装置的冲洗;(2)依据风机与风机、管束与管束之间反复切换的方式冲洗;(3)冲洗排汽装置等。给出了具体的冲洗原则及提高冲洗质量方法。 Directing against problems existing in the process of putting pulverous precoat filter into operation, a concrete flushing scheme for hot - state flushing of the direct air- cooled unit has been put forward: (1)not only flushing the air- cooled condenser and corresponding pipelines, but also flushing the drain pipelines and exhaust steam facility at the steam turbine side; (2) flushing has to be carried out according to the mode of repeatedly switching over between fan and fan, as well as between tubebandle and tubebandle; (3) flushing of the exhaust steam facility etc. has to be also carried out. The concrete flushing principle and method for enhancing the quality of flushing have been also given.
出处 《热力发电》 CAS 北大核心 2008年第12期51-53,共3页 Thermal Power Generation
关键词 直接空冷机组 精处理系统 覆盖过滤器 热态冲洗 direct air- cooled unit polishing treatment system pulverous precoat filter hot- state flushing