期刊文献+

心脏起搏自动阈值夺获功能的临床应用及研究进展 被引量:3

下载PDF
导出
摘要 自动阈值夺获功能可以使起搏器以既安全又有效的低能量起搏心脏,从而在保障安全的情况下延长起搏器的寿命。自动阈值夺获功能起搏器的电极已具备相当的兼容性。自动阈值夺获功能也被应用于ICD、CRT、心房自动阈值夺获等领域中的研究,均得到了较好的结果。
出处 《中国心脏起搏与心电生理杂志》 2008年第6期554-556,共3页 Chinese Journal of Cardiac Pacing and Electrophysiology
  • 相关文献

参考文献24

  • 1Preston TA, Fletcher RD, Lucchesi BR, et aL Changes in myocardialthreshold : physiologic and pharmacologic factors in patients withimplanted pacemakers[ J]. Am Heart, 1967,74:235.
  • 2耿仁义,朱中林,华伟.实用心脏起撙技术[M].北京:人民军医出版社,2004.39-40.
  • 3Izzet E, Ahmet A, Erten O, et al. Long-term follow-up of pacemakers with an autoeapture pacing system[J ]. Jpn Heart,2002,43: 631.
  • 4Luria D, Gurevitz O, Bar Lev D, et al. Use of automatic threshold tracking function with non-low polarization leads: risk for algorithm malfunction[JJ. PACE,2004,27(4) :453.
  • 5Johannes S, Bernd N,Ewald H, et al. Acute performance evaluation of a new ventricular automatic capture algorithm [J ]. Europace, 2006,8:65.
  • 6Sperzel J, Pitschner HF, Schwarz T, et al. Automatic capture verification in ICD lead systems using intracardiac ventricular evoked response and reduced coupling capacitance [ J ]. Europace,2003,5 : 83.
  • 7郭继鸿.起搏器的自动化功能——兼谈Kappa700起搏器(续)[J].中国心脏起搏与心电生理杂志,2002,16(6):417-423. 被引量:18
  • 8Nurnberg J-H, Abdul-Khaliq H, Ewert P, et al. Antibradycardia pacing in patients with congenital heart disease: experience with automatic threshold determination and output regulation (AutocaptureTM [ J ]. Europace ,2003,5 : 199.
  • 9Bauersfeld U, Bernd N,Luciano M, et al. Low-Energy Epicardial Pacing in Children: The Benefit of Autocapture [ J ]. Ann Thorac Surg, 1999,68 : 1 380.
  • 10Cohen MI,Buck K,Tanel RE, et al. Capture management efficacy in children and young adults with endocardial and Unipolar epicardial systems[ J]. Europace, 2004,6:248.

二级参考文献7

  • 1钱剑安,顾刚,方祖祥.延长起搏器电池寿命的程控和计算方法[J].中国心脏起搏与心电生理杂志,1996,10(3):163-164. 被引量:7
  • 2钱学贤 杨兴生.现代冠心病监护治疗学[M].北京:人民军医出版社,1994.388.
  • 3Sermasi S,Marconi M,Libero L,et al.Italian experience with autocapture in conjunction with a membrane lead:pacesetter automatic control of energy and membrane automatic threshold evaluation (Pacemate) study group[J].Pacing Clin Electrophysiol,1996,19(11):1799-1804.
  • 4Schuehert A,Ventura R,Meinertz T.Adjustment of the evoked response sensitivity after hospital discharge in pacemaker patients with automatic ventricular threshold tracking activated[J].Pacing Clin Electrophysiol,2001,24 (2):212-216.
  • 5Greenberg S,Grossley G,Ellenbogen K,et al.Clinical experience with evoked response and polarization testing in the Microny/Regency SR + Pacemakers:clinical efficacy of autocapture[J].PACE,1997,20(4):1172.
  • 6赵建荣,周志宏,钱剑安.117例低能量起搏患者的长期随访观察[J].中国心脏起搏与心电生理杂志,1998,12(1):26-27. 被引量:3
  • 7张琪,章隆泉,周哲慧,刘辉,刘建平,王彬尧.自动夺获起搏器的临床应用[J].上海第二医科大学学报,2000,20(2):132-134. 被引量:2

共引文献20

同被引文献26

  • 1刘志华,宋建平,汪康平,蒋文平.植入起搏电极参数的测定和随访[J].心脏起搏与心电生理杂志,1995,9(4):191-193. 被引量:7
  • 2苑翠珍,许原,郭继鸿,赵京.自动阈值夺获型起搏器心室除极波值与QRS波振幅的相关性研究[J].中国心脏起搏与心电生理杂志,2007,21(2):144-146. 被引量:3
  • 3Lau C,Cameron DA,Nishimura SC,et al.A cardiac evoked response algorithm providing threshold tracking:A North American multicenter study.Pacing Clin Electrophysiol,2000,23:953-959.
  • 4Sperzel J,Siemon G,Presser HJ,et al.Benefit of enhanced ventricular capture management in automated pacemakers.Europace,2004,6(suppl):51.
  • 5Sperzel J,Kennergren C,Biffi M,et al.Clinical performance of a ventricular automatic capture verification algorithm.Pacing Clin Electrophysiol,2005,28:933-937.
  • 6De Voogt WG,Vonk BF,Albers BA,et al.Understanding capture detection.Europace,2004,6:561-569.
  • 7Curtis A,Maas S,Domijan A,et al.A method for analysis of the local atrial evoked response for determination of atrial capture in permanent pacing systems.Pacing Clin Electrophysiol,1991,14:1576-1581.
  • 8Butter C,Hartung W,Kay G,et al.Clinical validation of new pacing in pacemakers.J Cardiovasc Electrophysiol,2001,10:1104-1108.
  • 9Boriani G,Biffi M,Cameron D,et al.Atrial evoked response integral for automatic capture verification in atrial pacing.Pacing Clin Electrophysiol,2003,26:248-252.
  • 10Rueter J,Heymen H,Meisel E,et al.Automatic measurement of atrial pacing thresholds by AV conduction.Pacing Clin Electrophysiol,2000,23:658.

引证文献3

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部