摘要 血管封堵器在冠状动脉介入术后,用于股动脉穿刺点止血,具有止血快、效果好、并发症少、病人舒适度提高等优点,但在实际使用过程中也出现了穿刺处出血及局部血肿形成等并发症。从适应证选择、植入操作、病人配合及护理方面探讨可能引起出血及局部血肿出现的原因及应对措施。
作者 王露
出处 《全科护理》 2008年第32期2946-2947,共2页 Chinese General Practice Nursing
  • 相关文献

参考文献4

二级参考文献21

  • 1陈少萍,秦永文.血管封堵器在心导管术后的应用[J].心血管病学进展,2004,25(6):407-409. 被引量:2
  • 2[3]Bogart DB, Bogart MA, Miller JT, et al. Femoral artery catheterization complications: a study of 503 consecutive patients[J]. Cathet Cardiovasc Diagn,1995,34(1):8-13.
  • 3[5]Christophe T, Rene K,Helene E, et al. A randomized comparison of a percutaneous suture device versus manual compression for femoral artery hemostasis after PTCA[J]. J Interven Cardiol, 2003,16(3):217-221.
  • 4[6]Eric KH, Robert B. Percutaneous arterial clousure device[J]. J Vasc Interv Radiol, 2003,14(7):865-885.
  • 5[7]Steven CW, Carin FG, David JE, et al. Complications of a percutaneous sutured-mediated closure device versus manual compression for arteriotomy closure: a case-controlled study[J]. J Vasc Interv Radiol, 2003,14(6):735-741.
  • 6[8]Daniel BB. Current status of suture-mediated closure: what is the cost of comfort[J]? J Vasc Interv Radiol,2003,14(6):677-681.
  • 7[9]Kussmaul GW, Buchbinder M, Whitlow PL, et al. Rapid arterial hemostasis and decressed access site complications after cardiac catheterization and angiography: results of a randomized trial of a novel hemostatic device[J]. J Am Coll Cardiol,1995,25(9):1685-1692.
  • 8[10]Duffin DC, Muhlestein JB, Allisson SB, et al.Femaral arterial puncture management after percutaneous coronary procedure:a comparison of clinical outcomes and patient satisfaction and two different vascular closure devices[J]. Invasive Cardiol, 2001,13(5):354-362.
  • 9[11]Sesana M, Vaghetti M, Albiero R, et al. Effectiveness and complications of vascular access closure devices after interventional procedures[J]. J Invas Cardiol, 2000,12(8):395-399.
  • 10[12]Kapadia SR, Raymond R, Konpf W, et al. The 6Fr Angioseal arterial closure device: results from a multimember prospective registry[J]. Am J Cardiol, 2001,87(4):789-791.

共引文献24

同被引文献16

  • 1孙国平,张彦舫,窦永充.血管封堵器的临床应用[J].中国医学影像技术,2004,20(8):1253-1255. 被引量:19
  • 2冯小弟,金贤,陈跃光,肖红兵,余强,陈诚军,张大东.三种股动脉血管封堵器应用疗效比较[J].介入放射学杂志,2007,16(6):411-413. 被引量:10
  • 3Wagner SC,Gonsalves CF,Eschelman DJ. Complications of a percutaneous suture-mediated closure device versus manual compression for arteriotomy closure:a case-controlled study[J].{H}JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY,2003,(06):735-741.
  • 4Nikolsky E,Mehran R,Halkin A. Vascular complications associated with arteriotomy closure devices in patients undergoing percutaneous coronary procedures:a meta-analysis[J].{H}Journal of the America College of Cardiology,2004,(06):1200-1209.
  • 5Steinkamp HJ,Werk M,Beck A. Excimer laser-assisted recanalisation of femoral arterial stenosis or occlusion caused by the use of Angio-Seal[J].{H}EUROPEAN RADIOLOGY,2001,(08):1364-1370.
  • 6Van Den Broek T,Liqui LPF,Suttorp MJ. Vascular occlusion as a late complication of the Angio-Seal closure device.A review of literature[J].{H}Minerva Cardioangiologica,2007,(06):815-819.
  • 7Siani A,Accrocca F,Gabrielli R. Management of acute lower limb ischemia associated with the Angio-Seal arterial puncture closing device[J].Interactive Cardio Vascular and Thoracic Surgery,2011,(03):400-403.
  • 8Copelen K. Improving productivity with the Angio-Seal device[J].Cath Lab Digest[Current Innovations in Vascular Sealing Suppl],2000.4-6.
  • 9Blanc R,Mounayer C,Piotin M. Hemostatic closure device after carotid puncture for stent and coil placement in an intracranial aneurysm:technical note[J].{H}AMERICAN JOURNAL OF NEURORADIOLOGY,2002,(06):978-981.
  • 10蒋米尔.临床血管外科学[M]{H}北京:科学出版社,2003.

引证文献1

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部