期刊文献+

Method for converting in-situ gamma ray spectra of a portable Ge detector to an incident photon flux energy distribution based on Monte Carlo simulation 被引量:3

Method for converting in-situ gamma ray spectra of a portable Ge detector to an incident photon flux energy distribution based on Monte Carlo simulation
下载PDF
导出
摘要 A matrix stripping method for the conversion of in-situ gamma ray spectrum, obtained with portable Ge detector, to photon flux energy distribution is proposed. The detector response is fully described by its stripping matrix and full absorption efficiency curve. A charge collection efficiency function is introduced in the simulation to take into account the existence of a transition zone of increasing charge collection after the inactive Ge layer. Good agreement is obtained between simulated and experimental full absorption efficiencies. The characteristic stripping matrix is determined by Monte Carlo simulation for different incident photon energies using the Geant4 toolkit system. The photon flux energy distribution is deduced by stripping the measured spectrum of the partial absorption and cosmic ray events and then applying the full absorption efficiency curve. The stripping method is applied to a measured in-situ spectrum. The value of the absorbed dose rate in air deduced from the corresponding flux energy distribution agrees well with the value measured directly in-situ. A matrix stripping method for the conversion of in-situ gamma ray spectrum, obtained with portable Ge detector, to photon flux energy distribution is proposed. The detector response is fully described by its stripping matrix and full absorption efficiency curve. A charge collection efficiency function is introduced in the simulation to take into account the existence of a transition zone of increasing charge collection after the inactive Ge layer. Good agreement is obtained between simulated and experimental full absorption efficiencies. The characteristic stripping matrix is determined by Monte Carlo simulation for different incident photon energies using the Geant4 toolkit system. The photon flux energy distribution is deduced by stripping the measured spectrum of the partial absorption and cosmic ray events and then applying the full absorption efficiency curve. The stripping method is applied to a measured in-situ spectrum. The value of the absorbed dose rate in air deduced from the corresponding flux energy distribution agrees well with the value measured directly in-situ.
出处 《Nuclear Science and Techniques》 SCIE CAS CSCD 2008年第6期358-364,共7页 核技术(英文)
关键词 蒙特卡罗模拟 探测器 伽马射线 拆模仿式 Monte Carlo simulation, Ge detector, Gamma radiation, Geant4, Stripping
  • 相关文献

参考文献16

  • 1Heifer L, Miller K. Health Phys, 1988, 55: 15-29.
  • 2Cutshall N, Larsen J. Health Phys, 1986, 51: 53-59.
  • 3Beck H L, De Campo J, Gogolak C V. ln-situ Ge(Li) and NaI(T1) gamma-ray Spectrometry. New York: US Department of Energy, 1972. HASL-258.
  • 4Miller K M, Shebell R In situ gamma-ray spectrometry. A tutorial for environmental radiation scientists. New York: Department of Energy, 1993. Report EML-557.
  • 5Askri B, Manai K, Trabelsi A, et al. Radiat Prot Dosimetry, 2007, doi: 10.1093/rpd/ncm426.
  • 6Clouvas A, Xanthos S, Antonopoulos-Domis M, et al. Health Phys, 2000, 78(3): 295-302.
  • 7Saito K, Jacob P. Radiat. Protect. Dosim, 1995, 58:29-45.
  • 8Rodenas J, Rius V. Application of Monte Carlo method to the simulation of Ge-detector calibration, in Proceedings of the Topsafe98, Valencia, Spain. 1998.15-17.
  • 9Hurtado S, Garcia-Leon M, Garcia-Tenorio R. Nucl. Instrum. Methods A, 2003, 518: 764-774.
  • 10Korun M, Likar A, Vidmar T. Nucl Instrum Methods A, 1997, 390: 203-208.

同被引文献13

引证文献3

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部