期刊文献+

硼的电子探针定量分析与质量吸收系数 被引量:5

Quantitative Analysis of Boron by EPMA and Absorption Coefficient
下载PDF
导出
摘要 本文用电子探针测量中的薄膜模型法测定了八种元素对BKα射线的质量吸收系数,与文献上查得的数据相比相差甚大。用几套数据代入修正公式进行反算,得到的强度比与实验测量的标准硼化物的强度比进行比较指出,我们的数据符合得较好。 Abstract Mass absorption coefficient (MAC) of BKα by eight elements was measured by means of EPMA with thin film model. In order to compare the accuracy of the MACs of the present work with that from references, the correction function was used to reversely calculate the X ray intensity ratio from MACs of present work and two sets MACs from reference separately. the results show that the X ray intensity ratio obtained from the present set of MACs is of better agreement with the ratio experimentally measured values.
出处 《电子显微学报》 CAS CSCD 1998年第1期78-82,共5页 Journal of Chinese Electron Microscopy Society
基金 自然科学基金
  • 相关文献

同被引文献36