以实际工程中U型玻璃幕墙结露和填充的塑料蜂窝保温芯材脱落现象为例,采用红外热成像分析和热工计算相结合的方法,分析幕墙结露以及保温芯材脱落的原因,并提出相应的解决措施。
Based on the phenomenon of condensation and cellular plastics insulation materials fell off in U-glass curtain wall in actual projects, this paper reveals the reasons for occur by using the infrared thermal imaging measure combined with thermal calculation,and puts forward a corresponding solutions in the end.
出处
《墙材革新与建筑节能》
2008年第12期60-62,共3页
Construction Wall Innovation & Building Energy-Saving