期刊文献+

胶体金免疫层析法和ELISA法在HBsAg检测中的方法学评价 被引量:4

Evaluation of gold immunochromatography and ELISA assay for HBsAg detection
下载PDF
导出
摘要 目的:对胶体金免疫层析法(GICA)和ELISA两种方法检测HBsAg进行方法学比较。方法:用胶体金纸条和ELISA试剂同时检测HBsAg血清标本。结果:与ELISA相比,胶体金免疫层析法检测HBsAg的灵敏度为96%,特异性为100%。胶体金免疫层析法与ELISA相比特异性基本一致,但胶体金免疫层析法灵敏度稍差。结论:HBsAg胶体金纸条与ELISA试剂相比有较高的特异性,但灵敏度有待于进一步提高。 Objective:To evaluate the gold immunochromatography (GICA) strips and ELISA assay for HBsAg detection. Methods:GICA strip method, as compared with ELISA assay, was used to detect HBsAg in serum sample. Results:Compared with ELISA assay, the sensitivity of GICA for HBsAg detection was 96%, the specificity was 100%.The above results showed that the specificity between GICA and ELISA was almost coincidence,but the sensitivity of GICA was slightly lower. Conclusion:In spite of further improvement of it's sensitivity,GICA strips method is likely to accord with ELISA assay very well.
作者 隋菊英
出处 《中国医药导报》 CAS 2008年第36期81-82,共2页 China Medical Herald
关键词 乙型肝炎表面抗原 胶体金免疫层析法 ELISA法 Hepatitis B surface antigen GICA ELISA assay