摘要
针对异步电动机直接启动时额定电流过大的问题,提出了以PLC为核心的液阻软启动装置,通过实验证明液阻软启动能将启动电流控制在额定电流的1.5~2倍,从而使电机具有平滑的启动性能。本文重点叙述了液阻软启动技术装置的系统构成、工作原理、优点和应用。
The text puts forward a device based PLC as the core of water-resistance soft-start for motor asynchronous commencement of direct current rating that is too great. It proves that liquid way can be soft-start to control the starting current as rated current of 1.5 to 2 times through experiments, in order having to a smooth motor starting performance. This paper describes mostly the structure of the system, operating principle, merits and application of water-resistance soft start technical devices.
出处
《气象水文海洋仪器》
2008年第4期71-74,共4页
Meteorological,Hydrological and Marine Instruments
基金
吉林省科学技术厅资助项目(合同编号:20060402)
关键词
PLC
异步电动机
液阻
软启动技术
PLC
motor asynchronous
water-resistance
soft-start technology