摘要
介绍了九江发电厂三期2×350MW机组运用等微增原理,根据各机组微增煤耗制定出机组负荷优化分配方案,以指导机组负荷优化分配,实现经济调度和经济运行。同时,对进一步细化和改进负荷优化分配系统和方案,全面体现效益最大化,提出了建议和措施。
The application of the equal incremental principle to 2 × 350 MW of Jiujiang Power Plant Ⅲ stage project is introduced. According to each unit' s micro - increment coal consumption, the optimal loading distribution scheme has been framed to instruct optimal loading distribution, realize economic dispatch and op- eration. Meanwhile, several suggestions and measures for the optimal loading allocation system and scheme being further refined and improved are put forward for the full realization of maximum benefit.
出处
《江西电力职业技术学院学报》
CAS
2008年第4期32-34,共3页
Journal of Jiangxi Vocational and Technical College of Electricity
关键词
机效
炉效
厂用电率
等微增
负荷分配
经济运行
turbine efficiency
bolier efficiency
station service power consumption rate
the equal incre-mental
loading allocation
economic operation