摘要
介绍了流动注射(FI)-氢化物发生(HG)与等离子体原子发射光谱(ICP-AES)联用技术以及应用于电解铜中痕量砷、锑、铋测定的研究,本法的RSD对砷、锑、铋分别为2.3、1.8、2.8%(n=11),方法的检出限分别为0.3、0.3、1.15μg/g。
The technique of flow injection hydride generation coupled with ICP AES and its application on determining trace As,Sb and Bi in electrolytic copper was investigated.An effective method was established ,the RSD for determination of As,Sb,Bi was 2.3,1.8,2.8%( n =11),and the detection limit was 0.3,0.3,1.15μg/g respectively.
出处
《分析试验室》
CAS
CSCD
1998年第1期57-59,共3页
Chinese Journal of Analysis Laboratory