提出沉淀滴定I-的新方法,以聚乙烯醇(PVA)作为沉淀的胶体保护剂,(I)-3(碘钅翁离子)作为吸附指示剂,用AgNO3标准溶液直接测定I-;讨论了滴定机理。检测范围为0.01~0.1mol/L,相对误差小于0.2%。本法已用于鸡饲料添加剂中I-的测定。
A new method was investigated for detection of iodine by using polyvinyl alcohol as reagent of protecting colloid and agueous AgNO 3 as standard solution. The detection range was 0.01~0.1mol/L. The relative error was less than 0.2%.This method has been successfully applied to the detection of I - in chicken feed additive.The titrating mechanism was also disscussed.
出处
《分析试验室》
CAS
CSCD
1998年第1期83-85,共3页
Chinese Journal of Analysis Laboratory