酶免法手工检测与全自动检测HBsAg结果的比较 被引量:2

Comparison between Manual ELISA and Automatic ELISA in the Detection of HBsAg
下载PDF
导出
摘要 目的了解酶免法手工检测与全自动检测HBsAg结果之间的总体及个体差异,为规范酶免检测提供实验数据。方法手工与全自动同时对同一组样本进行检测,运用统计学方法对获得的检测数据进行分析。结果手工检测变异系数为6.65%~21.38%,仪器检测变异系数为9.99%;结论各实验个体之间存在较明显差异,手工操作需要规范。 [Objective] To understand the general and individual difference between manual ELISA and automatic ELISA in the detection of HBsAg and provide laboratory data for the standardization of ELISA detection. [Methods] The samples were detected simultaneously by both manual and automatic ELISA; statistical method was used to analyze the acquired detection data.[Results] The variation coefficient of the manual detection was between 6.65% and 21.38%, while that of the automatic detection was 9.99%. [Conclusion] Significant difference exists between individuals; manual operation should be standardized.
作者 陈保民
出处 《职业与健康》 CAS 2009年第1期29-31,共3页 Occupation and Health
关键词 酶联免疫吸附实验 手工操作 自动检测 ELISA Manual operation Automatic detection
  • 相关文献

参考文献1

  • 1董俊清.浅谈ELISA操作中失败的原因.实验医学与临床.成都:成都科技大学出版社,1997:260-261.