介绍了噪声的定义、国家标准及危害,探讨了综合写字楼设备的噪声源,分析了噪声与振动的传播途径,针对噪声产生的具体情况,论述了综合写字楼的噪声治理措施,提出了水泵及噪声大的设备最好布置在地下层的建议。
The paper introduces the definition, the national standard and the harmfulness of the noise, discusses the noise source of the equipment in the comprehensive office building, analyzes the transmission route of the noise and the vibration, discusses the noise control measure of the comprehensive office building according to the concrete situation of the noise, puts forward the suggestion that the pump and the noise equipment should be laid out in the subterranean layer.
出处
《山西建筑》
2009年第2期351-352,共2页
Shanxi Architecture
关键词
综合写字楼
设备噪声
噪声源
传播途径
治理