摘要 目的:研究标点法进行MRI和CT图像融合后的融合精度,以期为颅内肿瘤术后进行放射治疗的患者寻找更有效的图像融合方法及精度评价标准。方法:24例颅内肿瘤术后患者,在相同定位条件下进行MRI T1WI增强序列和术后定位CT扫描,采用Tris-Axes Landmark方法将其轴位MRI的T1WI增强序列与定位CT图像进行融合,寻找融合分数与融合误差之间的线性关系,并观察每例患者在三维空间的融合误差。结果:融合分数和融合误差之间存在较好的线性关系,相关系数r=-0.985,回归方程为y=-0.551 3x+5.351 4,据此回归方程推测,融合分数>6.61者均可满足临床融合需要。结论:标点法是放射治疗中一种较好的融合方法,能快速准确地定量评价MRI-CT融合精度,可应用于临床放射治疗中。 Objective : To study the accuracy of MRI-CT image registration in order to find a more effective method of image fusion and a standard for the evaluation of post-operative intra-eranial tumor radio- therapy. Methods: Twenty-four patients with intra-eranial tumor underwent MR Tl-weighed sequence and post-operative location CT scan under the same location condition. The trans-axial MR Tl-weighed sequence and CT image were registered and the correlation between registration scores and errors was ana- lyzed by the method of Tris-Axes Landmark. The linear registration errors were observed in the three-di- mensional space of every patient. Results: An improved linear correlation was found between registra- tion scores and errors ( r = - 0. 985, y = - 0.551 3x + 5.351 4 ). The registration met the clinical standard when the scores exceeded 6.61. Conclusion : Tris-Axes Landmark is a preferable registration method to be used in clinical radiotherapy for rapid and precise evaluation of MRI-CT image registration accuracy.
出处 《医学研究生学报》 CAS 2008年第12期1278-1281,1284,共5页 Journal of Medical Postgraduates
基金 南京军区南京总医院科研基金资助项目(批准号:2004027)
关键词 图像融合 放射治疗 Image registration Radiotherapy
  • 相关文献

参考文献12

  • 1王学涛,于金明,杨国仁,巩合义.PET-CT同机融合精度验证及在放疗靶区勾画中的应用[J].中华放射肿瘤学杂志,2005,14(3):204-207. 被引量:13
  • 2叶靖,许乙凯,刘岘,陆雪松,许鹏君,黄其鎏,蒋志强,吕国士.二步法磁共振预定位免疫成像对荷人结肠癌裸鼠增强作用的研究[J].医学研究生学报,2006,19(4):323-326. 被引量:1
  • 3季学满,武洪林,卢光明.动态对比增强灌注磁共振成像在颅脑肿瘤的应用[J].医学研究生学报,2004,17(1):87-89. 被引量:5
  • 4金志良,孙新臣,魏青.脑胶质瘤放射敏感性基因研究的进展[J].医学研究生学报,2007,20(7):763-765. 被引量:2
  • 5Cattaneo GM, Reni M, Rizzo G, et al. Target delineation in post-operative radiotherapy of brain gliomas : inter-observer variability and impact of image registration of MR(pre-operative) images on treatment planning CT scans [ J ]. Radiother Oncol, 2005, 75(2) .. 217-223.
  • 6Khoo VS,Adams EJ,Saran F, et al. A comparison of clinical target volumes determined by CT and MRI for the radiotherapy planning of base of skull meningiomas [ J ]. Int J Radiat Oncol Biol Phys, 2000 , 46(5) : 1309-1317.
  • 7Ferroli P, Franzini A, Marras C, et al. A simple method'to assess accuracy of deep brain stimulation electrode placement: preoperative stereo-tactic CT + postoperative MR image fusion [ J ]. Stereotaet Funct Neurosurg, 2004, 82 ( 1 ) : 14-19.
  • 8Krempien RC,Daeuber S, Hensley FW, et al. Image fusion of CT and MRI data enables improved target volume definition in 3D-brachytherapy treatment planning[ J]. Brachytherapy, 2003, 2(3) : 164-171.
  • 9Sannazzari GL, Ragona R, Ruo-Redda MG, et al. CT-MRI image fusion for delineation of volumes in three-dimensional conformal radiation therapy in the treatment of localized prostate cancer [J]. Br J Radiol, 2002 , 75(895):603-607.
  • 10Barillot I, Reynaud-Bougnoux A. The use of MRI in planning radiotherapy for gynaecological tumors[J]. Cancer Imaging, 2006,6(5): 100-106.

二级参考文献53

共引文献29

同被引文献30

引证文献4

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部