摘要 针对高校浴室热水使用特点,提出洗浴废水余热回收和利用系统方案,并对其废热回收和利用效率以及经济性进行分析。采用该方案可减少燃气燃料43.7%,节省运行费用30.8%,并提出在进行浴室废水余热回收和利用中需要解决的技术问题。 Based on the characteristics of heat water in bathhouse in college,the paper described a new system to recover waste heat-carried by drainage water from bathhouse.Then it analyzed the efficiency and economic property,as the results,this system can decrease the amount of gas-consumed 43.7% and save the running cost 30.8%.In the end,the authors cleared the other problems needed to research in recovery of waste heat-carried by drainage water from bathhouse.
出处 《节能》 2009年第1期44-45,共2页 Energy Conservation
基金 北京市供热 供燃气通风与空调重点实验室项目
关键词 废热 回收与利用 经济性 水源热泵机组 waste heat recovery and utilization economic property water source heat pump unit