摘要
描述了早期变电站PT二次电压回路的设计特点,分析了其存在的缺陷、在电压回路日常维护及站内各种技术改造中引起的困难和安全隐患。通过对比,着重阐述了使用电压扩展屏的优点,建议在旧电站改造及新电站建设时可考虑使用电压扩展屏。
The design features of PT secondary, voltage circuit of early substation were described, the defects in which was analyzed. These defects caused some difficulties and potential safety hazard in daily maintenance of voltage circuit and technical reformations in substation. The advantages of using voltage extending panel were expounded emphatically by means of comparison. It is suggested that the men can consider using extending panel who would reform an old substation or construct a new substation.
出处
《华电技术》
CAS
2009年第1期53-54,65,共3页
HUADIAN TECHNOLOGY
关键词
电压扩展屏
电压回路
变电站
voltage extending panel
voltage circuit
substation