摘要
目的评估眼内压(intraocular pressure,IOP)测定用于无创颅内压(intracranial pressure,ICP)监测的可行性。方法34例(55例次)中枢神经系统疾病患者,通过腰椎穿刺测定ICP,同时采用双刻度Schiotz眼压计测量双眼IOP并计算其平均值。结果ICP与平均IOP之间呈显著正相关(r=0.765,P<0.01)。结论IOP与ICP具有相关性,通过测定IOP可反映ICP。
Objective To evaluate the feasibility of monitoring intracranial pressure (ICP) by determining intraocular pressure (IOP). Methods ICP (55 case times) in 34 patients with central neural system diseases was measured by lumbar puncture, and their IOP of both eyes was measured by two scales of Schiotz tonometer and the mean value was calculated. Results There was a significant correlation between ICP and mean IOP (P 〈 0. 01, r = 0. 765). Conclusion IOP is correlated well with ICP, thereby reflecting ICP.
出处
《第三军医大学学报》
CAS
CSCD
北大核心
2009年第2期163-165,共3页
Journal of Third Military Medical University
关键词
眼内压
颅内压
可行性
intraocular pressure
intracranial pressure
feasibility