期刊文献+

肺癌精准放射治疗中呼吸运动解决方案 被引量:7

Management of respiration motion in precise and accurate radiotherapy of lung cancer
下载PDF
导出
作者 李宝生
出处 《中华肿瘤防治杂志》 CAS 2008年第21期1601-1604,共4页 Chinese Journal of Cancer Prevention and Treatment
  • 相关文献

参考文献11

  • 1Jin J Y, Ajlouni M, Chen Q, et al. Quantification of incidental dose to potential clinical target volume (CTV) under different stereotactic body radiation therapy (SBRT) techniques for non-small cell lung cancer-Tumor motion and using internal target volume (ITV) could improve dose distribution in CTV[J]. Radiother Oncol,2007,85(2) :267-276.
  • 2Rietzel E, Pan T, Chen G T. Four-dimensional computed tomography: Image formation and clinical protocol[J]. Med Phys, 2005, 32(4) :874-889.
  • 3Wong J W, Sharpe M B, Jaffray D A, et al. The use of active breathing control (ABC) to reduce margin for breathing motion[J]. Int J Radiat Oncol Biol Phys, 1999, 44(4): 911-919.
  • 4闫婧,于金明,李宝生,付政,王学涛,周涛.主动呼吸控制系统在非小细胞肺癌精确放疗中的应用[J].癌症,2006,25(10):1311-1314. 被引量:14
  • 5Hanley J, Debois M M, Mah D, et al. Deep inspiration breathhold technique for lung tumors: the potential value of target immobilization and reduced lung density in dose escalation[J]. Int J Radiat Oncol Biol Phys,1999,45(3):603-611.
  • 6Shirato H, Shimizu S, Kunieda T, et al. Physical aspects of a real-time tumor-tracking system for gated radiotherapy[J]. Int J Radiat Oncol Biol Phys, 2000, 48(4):1187-1195.
  • 7Balter J M, Wright J N, Newell L J, et al. Accuracy of a wireless localization system for radiotherapy[J]. Int J Radiat Oncol Biol Phys, 2005,61(3) :933-937.
  • 8Xu T, Wong J T, Shikhaliev P M, et al. Real-time tumor tracking using implanted positron emission markers:concept and simulation study[J]. Med Phys, 2006,33(7):2598-2609.
  • 9Kini V R, Vedam S S, Keall P J, et al. Patient training in respiratory-gated radiotherapy[J]. Med Dosim,2003,28(1) :7-11.
  • 10Papiez L, Rangaraj D, Keall P. Real-time DMLC IMRT delivery for mobile and deforming targets[J]. Med Phys,2005,32(9): 3037-3048.

二级参考文献7

  • 1Langen K M,Jones D T.Organ motion and its management[J].Int J Radiat Oncol Biol Phys,2001,50(1):265-278.
  • 2Graham M V,Purdy J A,Emami B.Clinical dose-volume histogram analysis for pneumonitis after 3D treatment for non-small cell lung cancer (NSCLC)[J].Int J Radiat Oncol Biol Phys,1999,45 (2):323-329.
  • 3Tsujino K,Hirota S,Endo M.Predictive value of dose-volume histogram paramenters for predicting radiation pneumonitis after concurrent chemoradiation for lung cancer[J].Int J Radiat Oncol Biol Phys,2003,55(1):110-115.
  • 4Hanley J,Debois M M,Mah D.Deep inspiration breath-hold technique for lung tumors:the potential value of target immobilization and reduced lung density in dose escalation[J].Int J Radiat Oncol Biol Phys,1999,45(3):603-611.
  • 5Barnes E A,Murray B R,Robinson DM.Dosimetric evaluation of lung tumor immobilization using breath hold at deep inspiration[J].Int J Radiat Oncol Biol Phys,2001,50(4):1091-1098.
  • 6Cheung P C,Sixel K E,Tirona R.Reproducibility of lung tumor position and reduction of lung mass within the planning target volume using active breathing control (ABC)[J].Int J Radiat Oncol Biol Phys,2003,57(5):1437-1442.
  • 7李万龙,于金明,刘国华,仲伟霞,李文武,张百江.非小细胞肺癌影像学与病理学靶区关系的研究[J].中华肿瘤杂志,2003,25(6):566-568. 被引量:39

共引文献13

同被引文献57

引证文献7

二级引证文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部