期刊文献+

同步电机变频起动策略研究 被引量:2

Research on variable-frequency startup for synchronous motor
下载PDF
导出
摘要 较大容量的同步电机起动时,由于起动电流过大,会引起电网电压下降,从而影响其它用电设备正常工作,因此一般较大容量的同步电机起动时都要采用一些辅助措施。在介绍同步电机主要特性的基础上,详细论述了变频起动技术在同步电机起动过程中的原理、方式和效果,从而体现出变频起动在改善同步电机起动电流和转矩方面的优越性。 The impact on power grid and the bypass equipment which generates by exeessive surge current when synchronous motor starts directly, so startup of the larger capacity synchronous motor usually should adopt complementary measures. The main characteristics of synchronous motor is introduced, and the principle, method and effect of variable-frequeney technology used in the startup of synchronous motor are also discussed in detail. Accordingly, it incarnates the superiority of variable-frequency startup in the aspect of improving the start current and torque of synchronous motor.
作者 许容 刘鹏飞
出处 《电气传动自动化》 2008年第6期44-46,53,共4页 Electric Drive Automation
关键词 同步电机 变频起动 起动电流 synchronous motor variable-frequency startop start current
  • 相关文献

参考文献5

二级参考文献4

  • 1韩安荣.通用变频器及其应用[M].北京:机械工业出版社,2002..
  • 2陈坚.交流电机数学模型及调速系统[M].北京:国防工业出版社,2001..
  • 3谭弗娃.大功率电子学和电机控制[M].上海:上海交通人学出版社,2001..
  • 4佟纯厚. 现代交流调速[M]. 北京:冶金工业出版社, 1985.

共引文献125